| Specifications |
|
PFM 200N Series
Automotive Power Fail Simulator;
for OEM LV124 and LV 148 and other Manufacturer Standards
|
|
| Feature | Parameter |
| Power Line Switch |
|
| Switch | 2 Switches in the circuit
- DC+ Power line
- DC- Ground line
|
| DUT Voltage | ± 100 VDC |
| DUT Current | 100 mA to 100 A
200 A @ 25 °C
|
| Current Direction | Bidirectional |
| Switching Time | < 200 ns (rise/fall time) |
| Repetition Rate | 10 µs - 1 h |
| Drop Duration | 1 µs - 1 h |
| Peak Current | 400 A for 200 ms
1,350 A for 1 ms
automatic switch-off if I > 1,350 A
|
| Safety | Short circuit protection |
Switch for Signal
(and Dateline Switch)
|
|
| Channels | 16 independ switched lines |
| DUT Voltage | Max. ± 40 VDC |
| DUT Current | 100 µA to 2 A, per channel @ 25 °C |
| Current Direction | Bidirectional |
| Switching Time | < 1 µs (rise/fall time) |
| Repetition Rate | 500 µs - 1 h |
| Drop Duration | 1 µs - 1 h |
| Bandwidth | 50 MHz / 3 dB |
| Peak Current | 5 A for 200 ms |
| Safety | Short circuit protection |
| Connector | PHOENIX, DFMC connector
1.5 mm2
Push-in-spring cage connection
|
| General Switch |
|
| Switch Impedance | Power lines: < 50 mOhm
Data lines: < 500 mOhm
|
| Internal Switch | Short circuit switch
(DC+ to DC-), impedance <100 mOhm)
|
| Internal Switch | 100 mOhm, per LV 124 |
| Internal Switch | Low |
| Internal Switch | High |
| Trigger |
|
| Trigger Out | BNC Plug at the front panel, Automatic release of the events Trigger for oscilloscope, negative slope 15 V |
| Trigger In | BNC Plug at the front panel, External release of a single event Pull down |
| Protection |
|
| DC Input Protection | Max. voltage ±100 V
Clamped > 100 VDC
|
| DC Input Protection | Max. voltage ±40 V
Clamped > 40 VDC
|
| Over Temperature | NTC measurement on each mosfet switch |
| Over Current | On each mosfet switch electronic protection |
| Current Measurement | Overload measured at output |
| Interface |
|
| Frame bus | Control cable to AutoWave |
| Monitor Output | DUT out, differential,
BNC plug on front panel
Ratio 1:20
|
| Suitable BUS Systems for Dataline |
|
| BUS Systems | Low Speed Can 100 kbit
High Speed Can 500 kbit
LIN Bus 19200 Baud
FlexRay 10 Mbit
|
| General |
|
| Dimensions | 19"/3 HU
448 mm x 536 mm x 154 mm
|
| Weight | approx. 10.5 kg |
| Supply Voltage | 100 V - 265 VAC, 50/60 Hz |
| Fuses | 2 x 2 AT |
| Reference Temperature | 23 °C ±5 °C |
| Temperature | 10 °C to 35 °C |
| Humidity | 25 % to 75 %, non condensing |