Configured models contain the following attributes:
Power Supplies / Electronic LoadsRegenerative Power SuppliesPlease use 'Get Quick Quote' and we’ll contact you and quote for your exact need.
You can also get in touch, if you prefer, and our experts will be able to guide you with the right application and procurement solution for this product.
Please refer to the Resources section for Datasheets or see the Product Overview.
If you would like to know more, please get in touch and one of our team will be happy to help.
The bidirectional power supplies of series EA-PSBE 10000 are the economy variants of series EA-PSB 10000 and offer the same power of 30 kW in only 4U, the same connectivity with all interfaces, but save costs due to reduced software features.
All models incorporate two devices in one: a power supply (source) and an electronic load (sink) with energy recovery. Based on these two features the devices offer the functionality of two-quadrants operation as standard.
The internal electronic load achieves a high voltage dynamics by discharging unavoidable capacities on the DC terminal. For a connected source, the devices are full electronic loads with energy recovery, also ideal for bigger systems. In source operation mode the device becomes a flexible, autoranging power supply like those of series EAPSI 10000 4U. It incorporates the advantages of both device types into one and at the same time it eliminates the disadvantages of separate units regarding weight, space requirement, costs and effort to implement them into custom test software.
Key Features |
Wide range 342...528 V AC supply for operation on 380 V, 400 V or 480 V grids |
US 208 V models available |
Bidirectional device - power supply and electronic load in one |
Energy recovery with high efficiency |
Power rating: 30 kW (15 kW*) per device, expandable up to 1920 kW |
Voltage ratings: 60 V up to 2000 V |
Current ratings: 40 A up to 1000 A |
Flexible, power regulated DC<->AC stage |
Various protection circuits (OVP, OCP, OPP, OTP) |
5" TFT touch panel with display for values, status and notifications |
Remote sensing with automatic detection |
Galvanically isolated interfaces (USB, Ethernet, analog, slot) |
Optional, digital interface modules |
SCPI and ModBus command set |
LabView VIs and control software for Windows |
Note:
* US208V models
Benefits | |
AC Supply | All models are provided with an active Power Factor Correction (PFC) circuit and are designed for operation on a three-phase supply with typical worldwide ratings between 380 V and 480 V AC. But also regions where only 208 V three-phase is available are covered by the US 208 V models. During load operation, the device recovers the consumed DC energy and feeds it back into the local power network. This helps saving a lot of energy costs. |
Autoranging Power Stage | All models are equipped with a flexible autoranging bidirectional power stage which provides a higher output voltage at lower output current or a higher output current at lower output voltage, always limited to the max. rated output power. The same applies for sink mode operation. The power set value is adjustable with these models. Therefore, a wide range of applications can already be covered by the use of just one unit. |
DC Output/Input | DC voltages between 0...60 V and 0 ...2000 V, current ratings between 0...40 A and 0...1000 A are available, all along with a power rating of 0...30kW for all standard models, while the US 208 V models are rated with 0...15 kW. The DC terminal is located on the rear panel. |
Source-Sink Operation | One salient feature of these devices is the coalescence of an electronic load, also called sink, and a power supply, also called source, into one unit. It means, the device cannot only arbitrarily operate as sink or source, the switchover between these two operating modes occurs without interruption and time loss. This is also called two-quadrants operation. |
Energy Recovery | The most important feature of these devices is that the AC input while connected to the grid is also used as output for the recovery of the supplied DC energy during load operation, which is converted with an efficiency of up to 95.5%. This way of energy recovery helps to lower costs and can avoid expensive cooling systems, such as they are required for conventional electronic loads which only convert energy into heat. |
Master-Slave | All models feature a digital master-slave bus by default. It can be used to connect up to 64 units of identical models in parallel operation to a bigger system with totals formation of the actual value of voltage, current and power. This allows for a total power of up to 1920 kilowatts. The configuration of the master-slave system is either completely done on the control panels of the units or by remote control via any of digital communication interfaces. Handling of the master unit is possibly by manual or remote control (any interface). |
Display and Control Panel | Set values and actual values of input & output voltage / current / power are clearly represented on the 5" graphic display. The color TFT screen is touch sensitive and can be intuitively used to control all functions of the device with just a finger tip. Set values of voltage, current, power or resistance can be adjusted using the rotary knobs or entered directly via a numeric pad. To prevent unintentional operations, all operation controls can be locked. |
Analog Interface | There is a galvanically isolated analog interface terminal, located on the rear of the device. It offers analog inputs to set voltage, current, power and resistance from 0...100% through control voltages of 0 V...10 V or 0 V...5 V. To monitor the output voltage and current, there are analog outputs with 0 V...10 V or 0 V...5 V. Also, several inputs and outputs are available for controlling and monitoring the device status. |
Specifications | |
EA-PSBE 10500-180 4U 30000W Programmable Bidirectional DC Power Supply | |
Feature | Description |
Product Type | DC Laboratory Power Supply |
Rated Voltage and Range | 0...500 V |
Ripple (Source Mode) 1 | ≤525 mVPP / ≤105 mVRMS |
Insulation | Negative DC < - > PE: ±1500 V DC Positive DC < - > PE: +2000 V DC |
Rated Current and Range | 0...180 A |
Rated Power | 0...30 kW (0...15 kW) 4 |
Efficiency 5 | Up to 95.3% |
Weight 2 | ≈ 50 kg / 110 lb |
Note:
1 RMS value: measured at LF with BWL 300 kHz, PP value: measured at HF with BWL 20MHz
2 Weight of the standard version, models with option(s) may vary
3 WC = water-cooling
4 US 208 V models
5 Both directions, i. e. source and sink mode
Specifications | |
EA-PSBE 10000 4U Series Programmable Bidirectional DC Power Supply | |
Model Overview | |
Model | Description |
PSBE 10060-1000 4U | Rated Voltage and Range: 0...60 V Rated Current and Range: 0...1000 A Rated Power: 0...30 kW (0...15 kW) * |
PSBE 10080-1000 4U | Rated Voltage and Range: 0...80 V Rated Current and Range: 0...1000 A Rated Power: 0...30 kW (0...15 kW) * |
PSBE 10200-420 4U | Rated Voltage and Range: 0...200 V Rated Current and Range: 0...420 A Rated Power: 0...30 kW (0...15 kW) * |
PSBE 10360-240 4U | Rated Voltage and Range: 0...360 V Rated Current and Range: 0...240 A Rated Power: 0...30 kW (0...15 kW) * |
PSBE 10500-180 4U | Rated Voltage and Range: 0...500 V Rated Current and Range: 0...180 A Rated Power: 0...30 kW (0...15 kW) * |
PSBE 10750-120 4U | Rated Voltage and Range: 0...750 V Rated Current and Range: 0...120 A Rated Power: 0...30 kW (0...15 kW) * |
PSBE 11000-80 4U | Rated Voltage and Range: 0...1000 V Rated Current and Range: 0...80 A Rated Power: 0...30 kW (0...15 kW) * |
PSBE 11500-60 4U | Rated Voltage and Range: 0...1500 V Rated Current and Range: 0...60 A Rated Power: 0...30 kW (0...15 kW) * |
PSBE 12000-40 4U | Rated Voltage and Range: 0...2000 V Rated Current and Range: 0...40 A Rated Power: 0...30 kW (0...15 kW) * |
Note:
* US 208 V models