S970906B Spectrum Analysis for P50xxB up to 32 GHz
Add spectrum analysis to your P50xxB Streamline series vector network analyzer.
The S970906B spectrum analysis adds high-performance analysis to the P5006B and P5026B Streamline Series Vector Network Analyzers (VNA). With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over a broad frequency range. Make simultaneous spectrum measurements using multiple test and reference receivers.
Increase the efficiency of spurious signals measurements emanating from mixers and frequency converters using the multi-channel SA with internal swept-signal generators. The SA application employs source-power and receiver-response calibration and fixture de-embedding for in-fixture and on-wafer spectrum measurements with the highest level of accuracy.
Achieve accurate and fast noise power ratio (NPR) measurements by setting up and controlling external signal generator/arbitrary waveform generators and calibrating the flatness of a wideband signal and distortion signals in notches.
The installed SA license or the stop frequency of the instrument, whichever is smaller, determines the upper-frequency range of the SA application.
| KEY FEATURES |
| Fast spurious searches up to 32 GHz |
| Efficient multi-channel spectrum analysis with internal swept-signal generators |
| Very accurate in-fixture and on-wafer spectrum measurements using VNA calibration |
| Fast and accurate Noise Power Ratio (NPR) measurements |
Spectrum Analysis (with S97090xB)
This section provides specifications for spectrum analysis on the P50xxB Streamline Series VNA. S97090xB software is required to enable spectrum analysis functionality of the P50xxB.
| SPECIFICATIONS |
|
|
| Spectrum Analysis (with S97090xB) Frequency Specifications |
|
|
| Description | Specification | Typical |
| Frequency Reference 1 |
|
|
| Accuracy | -- | ± [(time since last adjustment x aging rate) + temperature stability + calibration accuracy], typical |
| Aging Rate | -- | ± 3 ppm/year maximum, typical |
| Temperature Stability | -- | ± 7 ppm (0 to 50 °C) |
| Achievable Initial Calibration Accuracy | ± 7 ppm (25 ± 5 °C) | -- |
| Frequency Readout Accuracy (Start, Stop, Center, Marker) | -- | ± [(readout frequency x frequency reference accuracy) + (< 1% x RBW)], nominal |
| Frequency Span |
|
|
| Minimum/Maximum | Analyzer’s full span | -- |
| Resolution | 1 Hz | -- |
| Sweep (Trace) Point Range | 11 to 100,003 | -- |
| Resolution Bandwidth (RBW) |
|
|
| Range (-3 dB bandwidth) | 10 Hz to 3 MHz in 10% steps | -- |
| Bandwidth Range Accuracy | -- | ± 1%, all RBW, except below 100 MHz with 3 MHz RBW |
| Selectivity (-60 dB/-3 dB) | -- | Gaussian: 4.5:1
Flat top: 2.47:1
Kaiser: 3.82:1
Blackman: 3.58:1
|
| Video Bandwidth (VBW) |
|
|
| Range | 10 Hz to 3 MHz | -- |
NOTE:
1 Frequency reference accuracy can be improved by using external frequency reference with better accuracy