Cette configuration a les caractéristiques suivantes:
Oscilloscope Probes10MHz <= 100MHzCliquez sur 'Obtenez un devis rapidement' ou 'Configurez votre produit' et nous vous contacterons pour vous adresser un devis conforme à votre besoin.
Vous pouvez cliquer sur Contactez-moi, si vous préférez, et nos experts vous guideront vers la bonne solution technique et financière.
| Attribut | Valeur |
|---|---|
| High Frequency (range) | 10MHz <= 100MHz |
The TCP300 and TCP400 Series AC/DC current measurement family is a highly advanced current measurement system for today's current measurement needs. When connected to Tektronix oscilloscopes with TEKPROBE Level II, TekConnect (w/ TCA-BNC), or TekVPI (w/ TPA-BNC) interfaces, current measurements and calculations are simple and easy.
The TCPA300 amplifier, when used with TCP312A, TCP305A, or TCP303 probes, provides a wide range of current measurement capability and spans the gap between low-level milliamp measurements to very high current levels. These three probes provide current measurement capabilities of 30 A, 50 A, and 150 A DC continuous. For even higher current levels, the TCPA400 amplifier with the TCP404XL current probe measures 500 A DC continuous and 750 A DC continuous, derated with duty cycle.
Higher-frequency performance is available with the TCP312A w/TCPA300 providing ≥100 MHz bandwidth and a maximum current of 30 A DC.
Key Performance Specifications:
AC/DC measurement capabilities
*Derated with duty cycle
Key Features:
**Requires a TDS TEKSCOPE oscilloscope or a TekConnect oscilloscope with TCA-BNC adapter
Applications:
| Specifications | ||||
| Model Overview | ||||
| Model | TCP312A w/ TCPA300 | TCP305A w/ TCPA300 | TCP303 w/ TCPA300 | TCP404XL w/ TCPA400 |
| Bandwidth | DC – 100 MHz | DC – 50 MHz | DC – 15 MHz | DC – 2 MHz |
| Rise Time | ≤3.5 ns | ≤7 ns | ≤23 ns | ≤175 ns |
| DC Accuracy | ±3% of reading | ±3% of reading | ±3% of reading | ±3% of reading |
| Accuracy, Typical | DC: ±1% of reading DC to 60 Hz, ≤5 A: ±1% 60 Hz – 5 kHz, ≤5 A: ±1.5% DC – 5 kHz, >5 A: ±1.5% | DC: ±1% of reading DC to 60 Hz, ≤5 A: ±1% 60 Hz – 5 kHz, ≤5 A: ±1.5% DC – 5 kHz, >5 A: ±1.5% | DC: ±1% of reading | DC: ±1% of reading |
Lowest measurable current (at ±3% accuracy at DC) Scope set to 1 mV/div and 20 MHz BW limited | 1 mA | 5 mA | 5 mA | 1 A |
| Maximum Amp-Second product, typical (based on amplifier range setting) | 50 A*μS – 1 A/V 500 A*μS – 10 A/V | 500 A*μS – 5 A/V NA – 10 A/V | 3,000 A*μS – 5 A/V 15,000 A*μS – 50 A/V | NA – 1 A/mV |
| Maximum Wire Voltage | ||||
| Bare | 150 V CAT II | 150 V CAT II | 600 V CAT I & II | 600 V CAT I & II |
| Insulated | 300 V CAT II | 300 V CAT II | 300 V CAT III | 300 V CAT III |
| AC-coupling low-Frequency Bandwidth, typical (Low pass – 3 dB point) | <7 Hz | <7 Hz | <7 Hz | <7 Hz |
| Displayed RMS Noise, typical (at 20 MHz Bandwidth limit) | ≤250 μARMS | ≤1.25 mA RMS | ≤2.5 mARMS | ≤250 mARMS |
| Signal Delay (to output BNC) | 17 ns | 19 ns | 40 ns | 80 ns |
| Insertion Impedance | 0.11 Ω at 1 MHz 0.12 Ω at 10 MHz 0.35 Ω at 50 MHz 0.7 Ω at 100 MHz | 0.02 Ω at 1 MHz 0.1 Ω at 10 MHz 0.35 Ω at 50 MHz | 0.01 Ω at 1 MHz 0.025 Ω at 5 MHz 0.1 Ω at 15 MHz | 0.1 m Ω at 10 kHz 0.6 m Ω at 100 kHz 8 m Ω at 1 MHz 16 m Ω at 2 MHz |



