The RTO6 oscilloscopes provides superior signals for insight into your applications. The large 15.6" touchscreen and streamlined GUI, combined with high waveform update rate, excellent signal fidelity, digital trigger and deep responsive memory serve as a fully integrated test solution for frequency, protocol and logic analysis. The rich measurement toolset for R&S®RTO6 oscilloscopes and streamlined user interface help quickly solve circuit issues, from simple to complex.
A high input sensitivity and very low inherent noise mean that R&S®RTO6 oscilloscopes are optimized to perform precise measurements. High-definition (HD) mode enables easy visualization and triggering on signals with up to 16 bit resolution. R&S®RTO6 oscilloscopes detect and display sporadic signal faults with an industry-leading update rate of up to 1 million waveforms/s.
Today's designs cross multiple measurement domains: time, frequency and protocol. RTO6 oscilloscopes simplify debugging of systems with different signal types by providing a flexible user interface that allows these domains to be viewed simultaneously. The Rohde & Schwarz digital trigger architecture also enables triggering on complex signal details. This unique trigger system even lets you specify “where” to trigger in the time or frequency domain simply by drawing a special zone directly on the waveform screen.
RTO6 oscilloscopes are extremely easy to use. The touchscreen-optimized GUI has gesture operations and the R&S SmartGrid function for complex screen layouts. Setting up intricate measurement tasks is only a matter of dragging waveforms to where they work best for you. The app cockpit provides a one-tap location to access all of the available oscilloscope applications.
| KEY FEATURES |
| 6 GHz maximum bandwidth |
| Bandwidth models: 600 MHz, 1 GHz, 2 GHz, 3 GHz, 4 GHz and 6 GHz |
| Sample rates: 600 MHz to 3 GHz Scopes - 10 Gs/sec |
| Sample rates: 4 GHz and 6 GHz Scopes - 20 Gs/sec |
| 1 million waveforms per second |
| 9.4 ENOB for ultimate signal integrity |
| 2 Gpoints maximum memory |
| Exclusive frequency zone trigger |
| BENEFITS |
|
Find Signal Anomalies Quickly
(with an unparalleled update rate)
| 1 000 000 waveforms/s
Available with active histograms masks or cursor measurements
Quickly and reliably detect sporadic signal faults
Mask testing: quick configuration and fast results
|
Captures all Signal Details
(with excellent signal integrity)
| Low-noise frontends and minimized crosstalk
Flat frequency response
Excellent long-term stability
Outstanding A/D converter with ultra-wide SFDR
|
Seeing More
(with up to 16 bit resolution)
| 16 bit resolution for measuring small signal amplitudes
High acquisition rate and full functionality
Full sample rate - no aliasing
User-selectable filtering: reduce noise, increased ENOB
|
Find Complex Signal Details
(with advanced trigger capabilities)
| Patented digital trigger system
High trigger sensitivity at full bandwidth
Isolate smallest signal details
Zone trigger in time and frequency domain
|
Measure More
(with deep and responsive memory)
| Maximized memory: 200 Mpoints standard
2 Gpoints optional
Segmented memory to capture distant trigger events
History mode to analyze previous trigger events
Search and navigation: find faults fast
|
| SPECIFICATIONS |
|
|
|
|
|
|
| RTO6 Oscilloscope Overview |
|
|
|
|
|
|
| Model | Order Number | Bandwidth | Channels | Sample Rate | Max. Memory Depth | Optional MSO |
| RTO64 | 1802.0001.04 | 600 MHz - 6 GHz | 4 | up to 20 Gsample/s | 2 Gpts | 16 digital channels |
| SPECIFICATIONS |
|
| RTO6 Oscilloscope Overview |
|
| Feature | Description |
| VERTICAL SYSTEM |
|
| Analog Channels | 4 |
| RTO64 with RT06-B90 Option | 600 MHz |
| RTO64 with RT06-B91 Option | 1 GHz |
| RTO64 with RT06-B92 Option | 2 GHz |
| RTO64 with RT06-B93 Option | 3 GHz |
| RTO64 with RT06-B94 Option | 4 GHz |
| RTO64 with RT06-B96Option | on 2 Channels: 6 GHz
on 4 Channels: 4 GHz
|