Cette configuration a les caractéristiques suivantes:
RF & Microwave Spectrum AnalyzersSpectrum Analyzers-Performance20GHz <= 50GHzDC <= 1kHzCliquez sur 'Configurez votre produit' et nous vous contacterons pour vous adresser un devis conforme à votre besoin.
Vous pouvez cliquer sur Contactez-moi, si vous préférez, et nos experts vous guideront vers la bonne solution technique et financière.
Attribut | Valeur |
---|---|
High Frequency (range) | 20GHz <= 50GHz |
Low Frequency (range) | DC <= 1kHz |
The Keysight N9038B is a standards-compliant MXE EMI test receiver and diagnostic signal analyzer built on an upgradeable platform. You choose the frequency coverage you need to fully test devices with outstanding accuracy and sensitivity across required ranges.
Key Features |
Perform EMC tests with a standard-compliant receiver: CISPR 16-1-1 & MIL-STD-461 |
Keep the test queue flowing with the accuracy, repeatability and reliability you need to test with confidence |
Reduce overall scan time with time domain scanning enabled by fast FFT scans |
Easily identify the frequencies of peak emissions prior to final measurement with monitor spectrum |
Get enhanced diagnostics using spectrum and real-time analysis, strip chart, markers, span zoom, zoom span, and spectrogram |
Evaluate emissions and identify suspect signals using EMC measurements through the front panel or remotely with software |
Benefits | |
The N9038B MXE EMI test receiver; (Is ideally suited for high-performance EMC testing and data analysis) | Simplify setup by recalling frequently used custom instrument settings. Accelerate data collection by viewing signal activity from multiple perspectives. Enjoy a consistent measurement framework and the broadest set of applications. Extend instrument longevity with easy upgrade paths. Leverage the proven reliability of a mature hardware platform |
Specifications | |
N9038B MXE EMI Test Receiver | |
Features | Parameters |
Bandwidth Options | 10 standard, 25, 85, 160 MHz |
DANL @1 GHz | -174 dBm |
Frequency | 3 Hz to 44 GHz |
Frequency Options | 3 Hz to 3.6, 8.4, 26.5, and 44 GHz |
Maximum Analysis Bandwidth | 160 MHz |
Maximum Real-Time Bandwidth | 160 MHz |
Performance Level | ◆◆◆◆◇◇ |
Phase Noise @1 GHz (10 kHz offset) | -114 dBc/Hz |
TOI @1 GHz (3rd Order Intercept) | +15 dBm |
Specifications | ||
N9038B MXE EMI Test Receiver | ||
Option Overview | ||
Model / Option | Description | Additional Information |
N9038B-503 | Frequency range, 3 Hz to 3.6 GHz | |
N9038B-508 | Frequency range, 3 Hz to 8.4 GHz | |
N9038B-526 | Frequency range, 3 Hz to 26.5 GHz | |
N9038B-544 | Frequency range, 3 Hz to 44 GHz | |
Preamplifier Option | ||
N9038B-P03 | Preamplifier, 100 kHz to 3.6 GHz | Compatible with frequency range option N9038B-503 |
N9038B-P08 | Preamplifier, 100 kHz to 8.4 GHz | Compatible with frequency range option N9038B-508 |
N9038B-P26 | Preamplifier, 100 kHz to 26.5 GHz | Compatible with frequency range option N9038B-526 |
N9038B-P44 | Preamplifier, 100 kHz to 44 GHz | Compatible with frequency range option N9038B-544 |
Frequency Reference | ||
Standard | Frequency reference | Aging rate: ± 1 x 10⁻⁶/year |
N9038B-PFR | Precision frequency reference | Reduces frequency drift for more accurate measurements Aging rate: ± 1 x 10⁻⁷/year |
Analysis Bandwidth | ||
Standard | 10 MHz analysis bandwidth | |
N9038B-B25 | 25 MHz analysis bandwidth | Extends the analysis bandwidth to 25 MHz |
N9038B-B85 | 85 MHz analysis bandwidth | Extends the analysis bandwidth to 85 MHz, below 3.6 GHz |
N9038B-B1X | 160 MHz analysis bandwidth | Extends the analysis bandwidth to 160 MHz, below 3.6 GHz |
Performance Options | ||
Standard | Digital processor with 2 GB capture memory | Licensed as N9038B-DP2 |
Standard | Noise floor extension | Improves displayed average noise level (instrument alignment based processes); licensed as N9038B-NFE |
Standard | Enhance display package | Includes spectrogram, trace zoom, and zone span; licensed as N90E1EDPB |
N9038B-CNF | Type-N RF connector, female | Choose Type-N RF connector for Input 1 |
N9038B-C35 | APC 3.5 mm connector, male | Choose 3.5 mm connector for Input 1 (Input 2 remains type-N); compatible with Option 526 only |
N9038B-EXM | External mixing | Provides external mixing with Keysight and third party mixers; single port for LO out and IF in (SMA female) |
N9038B-ESC | External source control | Controls EXG, MXG and PSG sources from the front panel of the MXE |
Rear Panel Output Utilities | ||
N9038B-CR3 | Wideband IF output | Wideband IF out; center frequency depends on IF path; output on Aux IF connector at rear panel |
N9038B-YAS | Y-axis screen video output | Screen video (0-1 volt open circuit) on rear panel analog out |
Security Features | ||
N9038B-SS2 | Additional removable solid-state drive (SSD) | Provides a fully-imaged, removable SSD in addition to the one installed in instruments, with Windows 10 operating system |
N9038B-SF1 | Exclude launch program | Prevents the launching of Windows programs from the instrument application |
N9038B-SF2 | Prohibit saving results | Prevents the saving/recall of measurement results or user configurations to/from instrument's data storage |