Oscilloscope Probes10MHz <= 100MHzPlease use 'Get Quick Quote' and we’ll contact you and quote for your exact need.
You can also get in touch, if you prefer, and our experts will be able to guide you with the right application and procurement solution for this product.
Attribute | Value |
---|---|
High Frequency (range) | 10MHz <= 100MHz |
Rohde&Schwarz current probes enable accurate, non-intrusive measurement of DC and AC currents. Different models are available to measure currents in the range of 1 mA to 2000 A with a maximum bandwidth of up to 120 MHz.
The R&S®RT-ZC current probes precisely measure direct and alternating current without interrupting the power circuit for the measurement. The extra-large opening on the R&S®RT-ZC10 accommodates conductors of up to 20 mm in diameter. The R&S®RT-ZC10 can measure peak currents up to 300 A (500 A for a single pulse). When measuring low-amplitude, high-frequency currents, the more compact R&S®RT-ZC20 with a measurement bandwidth of 100 MHz is ideal.
Rohde&Schwarz current probes are characterized by their robust design and easy operation. The degauss and offset correction is performed directly at the probe connector. The compact R&S®RT-ZA13 probe power supply supplies up to four current probes. The current probes can be selected as predefined probes on the R&S®RTO, R&S®RTE, R&S®RTM and R&S®RTA oscilloscopes.
Specifications | |||||
RT-Zxx Series | |||||
High Voltage and Current Probes | |||||
Model Overview | |||||
Model | Bandwidth | Sensitivity | Dynamic Range | Rise Time | Comment |
Current Probes | |||||
RT-ZC02 | 20 kHz | 0.01 V/A 0.001 V/A | ±200 A ±2000 A | 5 µs | Battery Powered |
RT-ZC03 | 100 kHz | 0.1 V/A | 20 A (RMS) ±30 A (peak | 1 µs | Battery Powered |
RT-ZC05B | 2 MHz | 0.01 V/A | 500 A (RMS) 700 A (peak) | 175 ns | Power Supply via Rohde&Schwarz probe interface |
RT-ZC10 | 10 MHz | 0.01 V/A | 150 A (RMS) ±300 A (peak) ±500 A (peak) (single pulse) | 35 ns | Power Supply via R&S®RT-ZA13 |
RT-ZC10B | 10 MHz | 0.01 V/A | 150 A (RMS) ±300 A (peak) ±500 A (peak) (single pulse) | 35 ns | Power Supply via Rohde&Schwarz probe interface |
RT-ZC15B | 50 MHz | 0.1 V/A | 30 A (RMS) ±50 A (peak) | 7 ns | Power Supply via Rohde&Schwarz probe interface |
RT-ZC20 | 100 MHz | 0.1 V/A | 30 A (RMS) ±50 A (peak) | 3.5 ns | Power Supply via R&S®RT-ZA13 |
RT-ZC20B | 100 MHz | 0.1 V/A | 30 A (RMS) ±50 A (peak) | 3.5 ns | Power Supply via Rohde&Schwarz probe interface |
RT-ZC30 | 120 MHz | 1 V/A | 5 A (RMS) 7.5 A (peak) | 2.9 ns | Power Supply via R&S®RT-ZA13 |
RT-ZC31 | 120 MHz | 0.1 V/A 1 V/A 10 V/A | 30 A (RMS) 5 A (RMS) 0.5 A (RMS) | 2.9 ns | Power Supply via R&S®RT-ZA13 |
Specifications | ||
RT-Zxx Series | ||
Model Overview | ||
Model | Order Number | Description |
RT-ZC02 | 1333.0850.02 | 20 kHz current probe, AC/DC, 0.01/0.001 V/A, 1000 A, 300 V (RMS) CAT III, BNC Including: operating manual |
RT-ZC03 | 1333.0844.02 | 100 kHz current probe, AC/DC, 0.1 V/A, 30 A, 300 V (RMS) CAT III, BNC Including: operating manual |
RT-ZC10 | 1409.7750K02 | 10 MHz current probe, AC/DC, 0.01 V/A, 150 A (RMS), BNC Including: carrying case operating manual |
RT-ZC20 | 1409.7766K02 | 100 MHz current probe, AC/DC, 0.1 V/A, 30 A (RMS), BNC Including: carrying case operating manual |
RT-ZC30 | 1409.7772K02 | 120 MHz current probe, AC/DC, 1 V/A, 5 A (RMS), BNC Including: carrying case operating manual |
RT-ZC31 | 1801.4932K02 | 120 MHz current probe, AC/DC, 0.1 V/A / 1 V/A / 10 V/A, 30 A (RMS), BNC Including: carrying case operating manual |
RT-ZC05B | 1409.8204.02 | 2 MHz current probe, AC/DC, 0.01 V/A, 500 A (RMS), Rohde & Schwarz probe interface Including: carrying case operating manual |
RT-ZC10B | 1409.8210.02 | 10 MHz current probe, AC/DC, 0.01 V/A, 150 A (RMS), Rohde & Schwarz probe interface Including: carrying case operating manual |
RT-ZC15B | 1409.8227.02 | 50 MHz current probe, AC/DC, 0.1 V/A, 30 A (RMS), Rohde & Schwarz probe interface Including: carrying case operating manual |