Home >> Products >> BAI-DX12
 
Other Configurations. Call our experienced Sales Staff.
 

Baker Instruments DX12

12kV Static Motor & Winding Analyzer

 
browse
View Data Sheet PDF icon
Part NumberIncluded Options
Rent/Lease   Buy Used
BAI-DX12/RLC/RLC Capabilities
Catalog Description

Baker Instruments DX12

 BAI-DX12 12kV Static Motor & Winding Analyzer



Input power: 100 - 240 Volts 50/60 Hz Universal supply

The SKF Static Motor Analyzer Baker DX unit offers more capabilities
to analyze all insulation and motor circuits in AC and DC motors, generators
and coils. These instruments can offer Insulation Resistance (IR),
Polarization Index (PI), Dielectric Absorption (DA), DC HiPot/Step
Voltage and Surge tests to evaluate all the insulation in motors and
coils. The motor circuit can also be analyzed utilizing Resistance,ments.
Impedance, Capacitance, Phase Angle and Dissipation Factor/Quality
Factor measurements.

DX benefits
*4 to 40 kV voltage testing capability to test fractional HP motors to
40 megawatt generators
*High and low voltage testing capability in one unit to test the motor circuit
and all the insulation
*Intuitive graphical user interface with touch screen
*USB printer interface to quickly print results
*Coil mode quickly analyze coils and store all data
*Impulse mode allows the operator to quickly apply voltage when testing coils
and DC motors
*Fully test DC motors
*Push to Test (PTT) lock to hold voltage during DC tests
*Modular design to meet your testing needs
*Internal test storage capacity 2 GB
*The Baker DX is the smallest, lightest 12 kV surge tester on the market

Surge
Capacitor size (nF): 40
Surge energy: 2,88 J
Short circuit current: 600 A
65 H load voltage: 12 kV
Surge voltage accuracy: 11%

DC tests
Voltage accuracy: 3%
Maximum resistance: > 500 G
Accuracy: 5%
Minimum resistance: 10 MOhm
Maximum output current: 3 mA
Over-current trip: 1,4 mA

Resistance
Source voltage, maximum: 3,9 V
Source current: 600 mA
10 000 to 200 000 : 3% accuracy
100 to 10 000 : 3% accuracy
0,2 to 100 : 2% accuracy
0,002 to 0,2 : 4%, 1 mOhm accuracy

Capacitance
Source voltage, maximum: 3,9 V
Source current, maximum: 600 mA
Source frequency: 50 to 4 000 Hz
0,001 to 2,6 F at 4 000 Hz: 3% accuracy
2,6 to 26 F at 4 000 Hz: 5% accuracy

Inductance
Source voltage, maximum: 3,9 V
Source current, maximum: 600 mA
Source frequency: 50 to 4 000 Hz
160 to 5 000 mH at 60 Hz: 3% accuracy
0,5 to 160 mH at 60 Hz: 2% accuracy
0,05 to 0,5 mH at 60 Hz: 3% accuracy

Impedance
Source voltage, maximum: 3,9 V
Source current, maximum: 600 mA
Source frequency: 50 to 4 000 Hz
0,15 to 10 000 at 60 Hz: 2% accuracy
0,01 to 0,15 at 60 Hz: 3% accuracy
Phase accuracy at 60 Hz: <2 deg.
LengthWidthHeightShip Wt 
23 " 19 " 8 " 60 lb  
    
N/A Currently not available for sale used