Home >> Products >> KT-E4446A
 
Keysight Technologies (formerly Agilent) E4446A
Other Configurations. Call our experienced Sales Staff.
 

Keysight Technologies (formerly Agilent) E4446A

3Hz-44GHz PSA Spectrum Analyzer

 
browse
View Data Sheet PDF icon
Part NumberIncluded Options
Rent/Lease   Buy Used
KT-E4446A/1DS/215/219/226/266/Internal Preamplifier/External Source Control/Noise figure measurement/Phase noise measurement/Programming code compatib
KT-E4446A/1DS/219/226/Internal Preamplifier/Noise figure measurement/Phase noise measurement
KT-E4446A/1DS/219/226/241/H70/Internal Preamplifier/Noise figure measurement/Phase noise measurement/Flexible digital modulat/70 MHz output
KT-E4446A/1DS/219/226/B7J/Internal Preamplifier/Noise figure measurement/Phase noise measurement/Digital demodulation hard
KT-E4446A/1DS/226/241/Internal Preamplifier/Phase noise measurement/Flexible digital modulat
KT-E4446A/1DS/226/B7J/Internal Preamplifier/Phase noise measurement/Digital demodulation hard
KT-E4446A/226/Phase noise measurement
KT-E4446A/226/AYZ/Phase noise measurement/External mixing
KT-E4446A/P3/15/111/115/122/123/1DS/+
Catalog Description

Keysight Technologies (formerly Agilent) E4446A

3Hz to 44GHz Performance Spectrum Analyzer (PSA).

Features:
1Hz to 8MHz Resolution Bandwidth.
Analysis bandwidth: 10MHz with option B7J, 40MHz with option 140, and
80MHz with option 122;
Phase noise at 10kHz offset -116dBc; at 100kHz offset-122dBc.
2dB step attenuator. Input connector 2.4mm male, 50-ohm.

Standard Features include:
All-digital IF with auto-ranging capability;
Phase noise optimization; Full detector suite;
160 resolution bandwidth settings (10% steps);
FFT and swept measurement modes;
Gated sweep; Power Suite one-button power measurements;
EMI precompliance measurements with CISPR compliant bandwidths and detectors.

Built in tests include adjacent channel power (ACP), channel power, occupied
bandwidth (OBW), emission bandwidth and harmonic distortion. Standard
interfaces include VGA, GPIB, Centronics parallel, and 10BaseT.

See also  KT-N9030A-544.

Hardware Option description:
Option 107 Audio input 100kohm
Option 110 10MHz-26.5GHz internal preamplifier
Option 111 USB device side I/O interface standard on units with serial numbers
US/MY4615xxxx or above
Option 115 512MB of memory standard on units with serial numbers US/MY4615xxxx
or above unless option 117 is installed
Option 117 Secure memory erase
Will require backup copy of HD and Keycodes prior to shipment
Option 124 Y-axis video output can only be added to PSA 6 or above
Units with serial number greater than US/MY/SG 4611 will require 324 upgrade.

Option 1DS 100kHz to 3GHz built-in preamplifier
Option B7J Digital demodulation hardware
Option H26 Highband Preamplifier, requires option 1DS
Option H70 70MHz IF output

Software descriptions:

Option 219 w/ option 1DS improves instrument uncertainty to 0.05dB below 3GHz

Option 241 provides a modulation analysis measurement personality
it also accesses Spectrum and Waveform measurements similar to Basic Mode.

Option 266, KT-8566B code compatibility, can be downloaded from Keysight's
web site at no charge. However, on some older units, it may automatically
disable any E444x series measurement personality installed. Option 266
can be removed, but any personalities disabled will have to be manually
reactivated by keycode.

Option compatibility and requirements:
Option 15 requires option 215
Option 107 requires option 233 and is not compatible with options 122,140
Option 110 is not compatible with option 1DS
Option 115 is not compatible with option 117
Option 122 is not compatible with options 107, 140 or H70
requires option 123 for frequencies above 3GHz
Option 123 is not compatible with option AYZ
Options 202, 204, 212, 233, B78, BAC, BAE, and BAF require option B7J
Option 210 requires options B7J and BAF
Option 212 requires option B7J
Option 213 requires options 212 and B7J
Option 214 requires options B78 and B7J
Option 219 requires option 1DS or 110 to meet published specifications,
serial numbers less than or equal to MY4100XXXX or US4222XXXX
will require option 119 hardware upgrade
Option 219 is not compatible with the KT-N400XA series noise source
For use with noise source use  KT-346B
Option AYZ is not compatible with option 123
Option H70 is not compatible with options 122 or 140

For rack mount kit, use KT-E444XA-1CP screen for more subs.

ER defined bundles:

Option N1 is a bundle of:
1DS RF internal preamplifier
219 Noise figure measurement personality
226 Phase noise measurement personality

Option P1 is a bundle of:
1DS RF internal preamplifier
219 Noise figure measurement personality
AYZ External mixing
B7J Digital demodulation hardware
H26 High band preamplifier
H70 70 MHz output

Option P2 is a bundle of:
1DS RF internal preamplifier
215 External Source Control Measurement Personality
226 Phase noise measurement personality
241 Flexible digital modulation analysis

Option P3 is a bundle of:
15 6GHz return-loss Measurement Accessory Kit
1DS RF internal preamplifier
111 USB device side I/O interface
115 512MB of memory
122 80MHz bandwidth digitizer
123 Switchable MW Preselector Bypass
215 External Source Control Measurement Personality
219 Noise figure measurement personality
226 Phase noise measurement personality
B7J Digital demodulation hardware



LengthWidthHeightShip Wt 
29 " 26 " 18 " 76 lb  
    
N/A Currently not available for sale used