配置型号包含以下特性:
LCR / Impedance AnalyzersSemiconductor Test EquipmentThe Keysight CX3300A series is an all-in-one measurement and analysis solution to solve your power rail, power delivery network, and power integrity challenges. The CX3300A series integrates an oscilloscope’s bandwidth and sampling rate, a DMM’s sensitivity, and data logger’s extended duration measurement recording with waveform analytics to reveal accurate current and voltage waveforms.
The CX3322A is a 2-channel mainframe series with 14-bit or 16-bit resolution. The memory depth and the bandwidth is upgradable up to 256 MSa/s and 200 MHz respectively. The OS supports Windows 10.
The CX3322A is a 2-channel model for engineers and researchers who need only one or two current waveform measurements at one time. Using a single channel current sensor (CX1101A, CX1103A, CX1104A) or a differential sensor (CX1105A) with a passive probe interface (CX1151A) enables power waveform measurements. The bandwidth options (50 MHz, 100 MHz and 200 MHz) and the memory depth options (4 Mpts/ch, 16 Mpts, 64 Mpts and 256 Mpts) are available.
Upgrades for both bandwidth and memory depth options are also available for CX3300 users who need more performance. The number of channels is not upgradable.
| KEY FEATURES |
| Wide bandwidth at 200 MHz |
| High-resolution/high-speed sampling at 14-bit (1GSa/s)/ 16-bit(75MSa/s) |
| Low noise and a wide dynamic range with high sensitivity from sub-nA and sub-μV |
| Long-duration measurement capabilities up to 100 hours maximum |
| Waveform analytics, current profiler and more efficient analysis functions on mainframe and PC |
| BENEFITS | |
| Mainframe Features | 2 analog channels for current and differential sensors and passive probe interface adapters Bandwidth options: 50 MHz, 100 MHz, 200 MHz Memory depth options: 4 Mpts/ch, 16 Mpts/ch, 64 Mpts/ch, 256 Mpts/ch WXGA 14.1” capacitive multi touch screen |
| Measurement Capabilities | 14-bit or 16-bit wide dynamic range Optimized to acquire low noise current sensor’s output 1 GSa/s acquisition and max. 200 MHz bandwidth Familiar trigger types and math functions available |
Available Current and Differential Sensors and Adapters (optional accessory products) | Current sensors: CX1101A, CX1102A, CX1103A, CX1104A Differential sensors: CX1105A Adapters: CX1151A |
| Analysis Capabilities | “Anywhere” zoom for in-depth waveform analysis Automatic power and current profiler Statistical analysis: histogram, CCDF Spectrum analysis (FFT) |
| SPECIFICATIONS | |
| Model: CX3322A | |
| Feature | Parameter |
| Analog Channels | 2 |
| Digital Channels | 0 |
| Maximum Sample Rate | 1 GSa/s |
| Maximum Memory | 256 Mpts/ch |
| ADC Resolution Options | 14 or 16 bits |
| SPECIFICATIONS | |
| Model: CX3322A Device Current Waveform Analyzer Overview | |
| Model - Option | Description |
| MAINFRAME | |
| CX3322A | Device Current Waveform Analyzer, 1 GSa/s, 14/16-bit, 2 Channel |
| BANDWIDTH OPTION | |
| CX3322A-B05 | Bandwidth – 50 MHz |
| CX3322A-B10 | Bandwidth – 100 MHz |
| CX3322A-B20 | Bandwidth – 200 MHz |
| MEMORY SIZE | |
| CX3322A-004 | Memory – 4 Mpts/ch |
| CX3322A-016 | Memory – 16 Mpts/ch |
| CX3322A-064 | Memory – 64 Mpts/ch |
| CX3322A-256 | Memory – 256 Mpts/ch |
| DATA LOGGER MODE | |
| CX3322A-STG | Data logger mode option |
| CALIBRATION | |
| CX3322A-A6J | ANZI Z540-1-1994 calibration |
| CX3322A-UK6 | Commercial calibration certificate with test data |
| PERIPHERALS | |
| CX3300A-KBD | Mini keyboard and optical mouse |
| SPECIFICATIONS | |
| Model: CX3324A Device Current Waveform Analyzer Overview | |
| Model - Option | Description |
| MAINFRAME | |
| CX3324A | Device Current Waveform Analyzer, 1 GSa/s, 14/16-bit, 4 Channel |
| BANDWIDTH OPTION | |
| CX3324A-B05 | Bandwidth – 50 MHz |
| CX3324A-B10 | Bandwidth – 100 MHz |
| CX3324A-B20 | Bandwidth – 200 MHz |
| MEMORY SIZE | |
| CX3324A-004 | Memory – 4 Mpts/ch |
| CX3324A-016 | Memory – 16 Mpts/ch |
| CX3324A-064 | Memory – 64 Mpts/ch |
| CX3324A-256 | Memory – 256 Mpts/ch |
| DATA LOGGER MODE | |
| CX3324A-STG | Data logger mode option |
| CALIBRATION | |
| CX3324A-A6J | ANZI Z540-1-1994 calibration |
| CX3324A-UK6 | Commercial calibration certificate with test data |
| PERIPHERALS | |
| CX3300A-KBD | Mini keyboard and optical mouse |
| SPECIFICATIONS | |
| CX11xx Sensor and Accessories Overview | |
| Model - Option | Description |
| CURRENT SENSOR | |
| CX1101A | Current sensor, single channel, ±40 V, 100 MHz, 40 nA – 1 A |
| CX1101A-A6J | ANZI Z540-1-1994 calibration |
| CX1101A-UK6 | Commercial calibration certificate with test data |
| CX1102A | Current sensor, dual channel, ±12 V, 100 MHz, 40 nA - 1 A |
| CX1102A-A6J | ANZI Z540-1-1994 calibration |
| CX1102A-UK6 | Commercial calibration certificate with test data |
| CX1103A | Current sensor, low-side, 200 MHz, 150 pA - 20 mA |
| CX1103A-A6J | ANZI Z540-1-1994 calibration |
| CX1103A-UK6 | Commercial calibration certificate with test data |
| CX1104A | Current sensor, selectable resistive sensor head, ±40 V, 20 MHz |
| CX1104A-A6J | ANZI Z540-1-1994 calibration |
| CX1104A-UK6 | Commercial calibration certificate with test data |
| CURRENT AND VOLTAGE SENSOR | |
| CX1105A | Differential sensor, single channel, 100 MHz |
| CX1105A-A6J | ANZI Z540-1-1994 calibration |
| CX1105A-UK6 | Commercial calibration certificate with test data |
| VOLTAGE SENSOR | |
| CX1151A | Passive probe interface adapter |
| CX1151A-A6J | ANZI Z540-1-1994 calibration |
| CX1151A-UK6 | Commercial calibration certificate with test data |
| DIGITAL CHANNEL | |
| CX1152A | Digital channel, 10 input, ±25 V, 8-channels |
| ACCESSORIES | |
| CX1903A | Rackmount kit for CX3300 series |
| CX1905B | Attachment for 3D probe positioner |