配置型号包含以下特性:
MultimeterData AcquisitionCounters & Function GeneratorsDigital Multimeters请参考资源中的资料文档或查看产品总览。
如果您想了解更多,请 联系,我们的团队将为您提供帮助。
The cabinet is already jammed, and now you're supposed fit in a current clamp, while wearing a full arc flash suit.
The CNX™ i3000 iFlex® AC Wireless Current Module gives you a better way. Deenergize. Slip the flexible current probe in between conductors. Close the cabinet and reenergize. Now you can view measurements from up to 20 meters away on the CNX™ Wireless Multimeter. Use multiple modules for easy measurements on three-phase systems. Plus, no more writing down data as the CNX™ i3000 Current Module captures up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. CNX™ wireless test tools also offer increased safety by letting you view readings in a separate location from the test point. Now you can take readings on moving machinery, with only the measurement module in harm's way.
| Key Features |
| iFlex® Current Probe allows you to get into tight, awkward spaces |
| True-rms ac current measurements to 2500 A, with 3% accuracy |
| Memory recording up to 65,000 readings |
| Backlit LCD Display |
| CAT IV 600 V, CAT III 1000 V |
Fluke CNX-
| Specifications | |
CNX-I3000 Current Module; 2500 Arms | |
| Model Overview | |
| Model | CNX-I3000 |
| Range | 2500 A AC |
| Resolution | 0.1A to 999.9, 1A from 1000 to 2500 |
| Accuracy | 3 % ± 5 digits |
| Crest factor (50 Hz/60 Hz) | 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2 |
| Display | 3-1/2 digits, LCD w/backlight |
| Log rate/interval | 1 sec minimum/adjustable by PC or front pane |
| Battery type | 2 AA, NEDA 15 A, IEC LR6 |
| Battery life | 400 hours |
| Memory record | up to 65,000 readings |
| Unbound listen interval | 5 seconds |
| RF communications | 2.4 GHZ ISM Band |
| RF communication range | 20 Meters |
| Operating temperature | -10 °C to +50 °C |
| Storage temperature | -40 °C to +60 °C |
| Operating humidity | 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C |
| EMC | EN 61326-1:2006 |
| Safety compliance | EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III 600 V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010 EN/IEC 610101-2-031:2002 EN/IEC 61010-2-032:2002 |
| Pollution degree | 2 |
| Temperature coefficient | Add 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C) |
| Safety rating | CAT IV 600 V, CAT III 1000 V |
| Certifications | CSA, FCC T68-FWCS IC:6627A-FWCS |
| Ingress Protection (IP) rating | IP42 |
| Size (HxWxD) | 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in) |
| Weight | .22 kg (8 oz) |
| Jaw opening | 25.4 cm (10 in) coil |