配置型号包含以下特性:
Oscilloscopes & Logic AnalyzersSampling Oscilloscopes50GHz <= 85GHz| 特性 | 参数 |
|---|---|
| High Frequency (range) | 50GHz <= 85GHz |
A three-slot wide DCA-X module that integrated two 50/85 GHz electrical channels with a clock recovery (CDR) and a precision timebase (PTB) to provide residual jitter as low as 45 fs for more accurate jitter measurements.
The Keysight N1060A precision waveform analyzer is a digital communications analyzer (DCA) module that is compatible with the Keysight N1000A mainframe. Like all of Keysight's DCA modules, the N1060A provides a wide range of configurations and performance options to interchange the bandwidth and clock recovery data rate of your oscilloscope solution.
| Key Features |
| Gain margin with high instrument performance: bandwidth to > 90 GHz, residual jitter as low as 45 fs, adjustable clock recovery peaking and loop bandwidth |
| Reduce validation time with analysis tools like jitter spectrum analysis and software clock recovery emulation |
| Reduce development time through instrument flexibility |
| Enjoy simple, one connection “triggerless” operation with integrated clock recovery data rates to 64 GBd (112 Gb/s) (NRZ and PAM4) and integrated pickoffs |
| Specifications | |
N1060A Precision Waveform Analyzer | |
| Features | Parameters |
| Applications | NRZ PAM4 |
| Bandwidth | > 90 GHz |
| Channels | 2 electrical with CRU & PTB |
| Input Type | 1.0 mm |
| Max Memory Depth | n/a |
| Max Sample Rate | Up to 250 KHz |
| Module Type | Electrical |
| Operating System | Windows 10 |
| Supported Filter Range | 16.5 GHz to 100 GHz |
| Type | Equivalent-Time |
| Specifications | |
| DCA-X Modules | |
| Model Overview | |
| Model | Description |
| N1000A | Infiniium DCA-X mainframe |
| 86100D | Infiniium DCA-X Wide-Bandwidth Oscilloscope Mainframe |
| Optical Electrical Modules * | |
| N1030A | Single 65 GHz optical channel, 9/125 μm fiber input |
| N1030B | Two 65 GHz optical channels, 9/125 μm fiber input |
| N1032A | Single 120 GHz optical channel, 9/125 μm fiber input |
| N1032B | Two 120 GHz optical channels, 9/125 μm fiber input |
| Dual/ Quad Electrical Channel Modules * | |
| N1040A | Dual electrical channel module |
| N1045B | 2/4 port 60 GHz electrical remote head |
| N1046A | 100 GHz, 1/2/4 port electrical remote sampling head |
| TDR/TDT Modules * | |
| N1055A ¹ | 35/50 GHz 2/4 Port electrical remote head module with TDR/TDT |
| Precision Waveform Analyzer Module * | |
| N1060A | Precision waveform analyzer ² (6) |
| External Clock Recovery Solutions Module * | |
| N1076B | Electrical clock recovery |
| N1077A | Optical/electrical clock recovery |
| N1077B | Optical/electrical clock recovery |
| N1078A | Optical/electrical clock recovery |
| DCA-M Sampling Oscilloscope Module * | |
| N1090A | Optical sampling oscilloscope |
| Optical DCA-M Sampling Oscilloscope Module * | |
| N1092A/B/D | Single optical channel oscilloscope |
| N1092B | Dual optical channel oscilloscope |
| N1092D | Quad optical channel oscilloscope |
| N1092C | Single optical, dual electrical channel oscilloscope |
| N1092E | Dual optical, dual electrical channel oscilloscope |
| Electrical DCA-M Oscilloscope Module * | |
| N1094A | Dual electrical channel oscilloscope |
| N1094B | Quad electrical channel oscilloscope |
Note:
* Please See Data Sheet in Resources for module options
¹ When used in an 86100D, 86100D option ETR is recommended if more than one TDR module is connected to the same DUT
² Module includes a custom System Impulse Response Correction (SIRC) file for each channel .
| Specifications | |
| Precision Waveform Analyzer Modules | |
| Model Overview | |
| Model | Description |
| N1060A-050¹ | Dual 50 GHz electrical channels |
| N1060A-085¹ | Dual 85 GHz electrical channels |
| N1060A-216 | Clock recovery 125 MBd to 16 GBd |
| N1060A-232 | Clock recovery 125 MBd to 32 GBd |
| N1060A-264 | Clock recovery 125 MBd to 64 GBd |
| N1060A-PTB | Integrated precision timebase (mandatory option²) |
| N1060A-E33 | Integrated hardware filters for 33 GHz, 40 GHz, and 43 GHz |
| N1060A-EVA | Integrated variable equalizers in clock path (mandatory option²) |
| N1060A-JSA | Jitter Spectrum Analysis (mandatory option²) |
| N1060A-A1F | Two 1 mm (f) to 1 mm (f) adapters |
| N1060A-A1M | Two 1 mm (m) to 1 mm (m) adapters |
| N1060A-A1X | Two 1 mm (m) to 1 mm (f) adapters |
| N1060A-CA1 | Cable pair, 1 mm (m) to 1 mm (f), 160 mm length |
| N1060A-CA2 | Matched cable pair, 2.4 mm (m) to 2.4 mm (m), 24 inch length |
| N1060A-DC2 | Two DC blocks, 2.4 mm connectors, 16V, 50 kHz to 50 GHz |
| N1060AU-085 | Upgrade to Option 085 Performance |
| N1060AU-264 | Upgrade to Option 264 |
| N1060AU-232 | Upgrade to Option 232 |
Note:
¹ 86100D option ETR recommended when used in an 86100D mainframe, N1000A option PLK recommended when used in an N1000A mainframe
² Mandatory options are automatically provided with the product and cannot be unselected.