The NSLK 8128 is an efficient and reliable V-LISN that supports a range of current and voltage configurations, ensuring accurate EMI testing results for high-performance systems.
SPECIFICATIONS
Model: NSLK 8128 – Line Impedance Stabilisation Network
Features
Parameters
Topology
V-LISN
Frequency Range
9 kHz – 30 MHz
Pre-filter Choke
250 µH
Impedance Simulation
50 Ω || (50 µH + 5 Ω)
Max. Current IEC 60309
4 x 32 A
Max. Current CEE 7/4 Socket
16 A
Max. Voltage
250 VAC 50/60 Hz; 400 VDC
Supply Cable
hard-wired five-wire connection cable with CEE plug (IEC 60309)
Connector for EuT
CEE 7/4 Type F (Schuko) socket and IEC 60309 3L+N+PE 32 A CEE socket
Connector for “artificial hand”
4 mm laboratory socket with screw terminal 6 mm, not removable