The N1045B 60 GHz remote sampling head module is engineered to provide superior measurement accuracy with the highest throughput for testing multi-lane electrical designs.
The Keysight N1045B electrical port sampling head is a digital communications analyzer (DCA) module that is compatible with the N1000A DCA-X mainframe. Keysight's DCA modules provide a wide range of configurations and performance options to interchange the bandwidth, channel count, and features of your oscilloscope solution.
| Key Features |
| 60 GHz bandwidth (65 GHz typical) |
| 2 or 4 channels per module (user-selectable option) |
| User-selectable bandwidth settings of 20 / 35 / 45 / 60 GHz |
| Electrical inputs: 1.85 mm male or female (user-selectable option), sample rate 250 kSa/s |
| Specifications |
|
N1045B
Electrical Remote Sampling Head Module
|
|
| Feature | Parameter |
| Applications | NRZ
PAM4
|
| Bandwidth | 60 GHz |
| Channels | 2/4 electrical remote head |
| Input Type | 1.85 mm |
| Instrument Type | Equivalent-Time |
| Max Memory Depth | n/a |
| Max Sample Rate | Up to 250 KHz |
| Module Type | Electrical |
| Operating System | Windows 10 |
| Supported Filter Range | 10 GHz to 70 GHz |
| Type: | Equivalent-Time |
| Specifications |
|
| DCA-X Modules |
|
| Model Overview |
|
| Model | Description |
| N1000A | Infiniium DCA-X mainframe |
| 86100D | Infiniium DCA-X Wide-Bandwidth Oscilloscope Mainframe |
| Optical Electrical Modules * |
|
| N1030A | Single 65 GHz optical channel, 9/125 μm fiber input |
| N1030B | Two 65 GHz optical channels, 9/125 μm fiber input |
| N1032A | Single 120 GHz optical channel, 9/125 μm fiber input |
| N1032B | Two 120 GHz optical channels, 9/125 μm fiber input |
| Dual/ Quad Electrical Channel Modules * |
|
| N1040A | Dual electrical channel module |
| N1045B | 2/4 port 60 GHz electrical remote head |
| N1046A | 100 GHz, 1/2/4 port electrical remote sampling head |
| TDR/TDT Modules * |
|
| N1055A ¹ | 35/50 GHz 2/4 Port electrical remote head module with TDR/TDT |
| Precision Waveform Analyzer Module * |
|
| N1060A | Precision waveform analyzer ² (6) |
| External Clock Recovery Solutions Module * |
|
| N1076B | Electrical clock recovery |
| N1077A | Optical/electrical clock recovery |
| N1077B | Optical/electrical clock recovery |
| N1078A | Optical/electrical clock recovery |
| DCA-M Sampling Oscilloscope Module * |
|
| N1090A | Optical sampling oscilloscope |
| Optical DCA-M Sampling Oscilloscope Module * |
|
| N1092A/B/D | Single optical channel oscilloscope |
| N1092B | Dual optical channel oscilloscope |
| N1092D | Quad optical channel oscilloscope |
| N1092C | Single optical, dual electrical channel oscilloscope |
| N1092E | Dual optical, dual electrical channel oscilloscope |
| Electrical DCA-M Oscilloscope Module * |
|
| N1094A | Dual electrical channel oscilloscope |
| N1094B | Quad electrical channel oscilloscope |
Note:
* Please See Data Sheet in Resources for module options
¹ When used in an 86100D, 86100D option ETR is recommended if more than one TDR module is connected to the same DUT