The output current of the CPC 100 can be increased up to 2000 A using the CP CB2 current amplifier. The CP CB2 is connected to the busbars via a short, high-current cable, and to the CPC 100 via the long control cable.
Package Components
|
|
Omicron VEHZ0630: CP CB2 Upgrade Option |
|
Hardware |
|
CP CB2 | 1 |
Cables and accessories |
|
Booster connection cable (20 m / 65,62 ft., 3 × 1.5 mm2) | 1 |
High current cable set for CP CB2 | 1 |
Grounding cable (green / yellow) (6 m / 19.68 ft., 6 mm2 ) | 1 |
Transport case for CP CB2 | 1 |
Specifications |
|
|
|
Omicron VEHZ0630 CP CB2 Current Booster |
|
|
|
Current Output | 1000 A AC3 | 1000 A AC3 | 2000 A AC4 |
Amplitude | 0 ... 500 A | 0 ... 1000 A | 0 ... 2000 A |
tmaxk1 | 30 min | 25 s | 25 s |
Vmax2 | 5.00 V | 4.90 V | 2.45 V |
Pmax2 | 2500 VA | 4900 VA | 4900 VA |
f | 15 - 400 Hz | 15 - 400 Hz | 15 - 400 Hz |
Typical Accuracy2 |
| 1000 A AC | 2000 A AC |
Amplitude | Reading | 0.13% | 0.13% |
| Full Scale | 0.13% | 0.13% |
Phase | Full Scale | 0.25 ° | 0.25 ° |
Guaranteed Accuracy2 |
| 1000 A AC | 2000 A AC |
Amplitude | Reading | 0.25% | 0.25% |
| Full Scale | 0.25% | 0.25% |
Phase | Full Scale | 0.50 ° | 0.50 ° |
Technical Data |
|
|
|
Output Current | up to 2000 A |
|
|
Dimension | 186 x 166 x 220 mm | 7.3 x 6.5 x 8.7 in |
|
Weight | 16.0 kg / 35.3 lbs |
|
|
Order Number | VEHZ0630 |
|
|
1 With mains voltage 230 V at 23 °C ± 5 °C (73 F ± 10 F) ambient temperature.
2 Signals below 50 Hz or above 60 Hz with reduced values possible.
3 Outputs in series.
4 Outputs in parallel.