The 3870 raises the bar for safety and efficiency in production line Hipot Testers. If your application requires AC or DC Withstand test, Ground Continuity, and Insulation resistance testing capabilities the 3870 is the electrical safety tester for you.
The Hypot Series Dielectric Withstand Tester provides a simple solution for you. This line of Electrical Safety testers is equipped with innovations that allow you to achieve industry leading test solutions, without the need for an expensive automated test system or connection to a PC. Improve efficiency and traceability with on-board data storage and data transfer capabilities. Automate your production line with direct barcode connection, which allows you to quickly associate products with pre-programed test files. Keep operators safe with SmartGFI®, Safety Interlock, and Personal Protective Equipment (PPE) compatible accessories.
| SPECIFICATIONS |
|
| Model: 38xx |
|
| Feature | Parameter |
| AC Hipot | Voltage Output = 0-5000VAC
Leakage Current Limits = 0.00-20.0mA
Output Frequency = 50/60HzΩ
|
| DC Hipot | Voltage Output = 0-6000VDC
Leakage Current Limits = 1µA-7.500mA
DC Ripple ≤ 5% Ripple RMS at 6KVDC @ 7.5mA, Resistive Load
|
| Ground Continuity | Current = DC 0.1A ± 0.01A, fixed
Resistance Limits = 0.0Ω-1.50Ω
|
| Insulation Resistance | Voltage Output = 30-1000VDC
Resistance Range = 1MΩ-50GΩ
|
| SPECIFICATIONS |
|
|
| 38xx Series Overview |
|
|
| Models | Test Capabilities | Test Specifications |
| 3805 | AC Hipot
Ground Continuity | AC Hipot
Voltage Output = 0-5000VAC
Leakage Current Limits = 0.00-20.0mA
Output Frequency = 50/60Hz
Ground Continuity
Current = DC 0.1A ± 0.01A, fixed
Resistance Limits = 0.0Ω-1.50Ω |
| 3855 | AC Hipot
Ground Continuity
Insulation Resistance | AC Hipot
Voltage Output = 0-5000VAC
Leakage Current Limits = 0.00-20.0mA
Output Frequency = 50/60Hz
Ground Continuity
Current = DC 0.1A ± 0.01A, fixed
Resistance Limits = 0.0Ω-1.50Ω
Insulation Resistance
Voltage Output = 30-1000VDC
Resistance Range = 1MΩ-50GΩ |
| 3865 | AC Hipot
DC Hipot
Ground Continuity | AC Hipot
Voltage Output = 0-5000VAC
Leakage Current Limits = 0.00-20.0mA
Output Frequency = 50/60Hz
DC Hipot
Voltage Output = 0-6000VDC
Leakage Current Limits = 1µA-7.500mA
DC Ripple ≤ 5% Ripple RMS at 6KVDC @ 7.5mA, Resistive Load
Ground Continuity
Current = DC 0.1A ± 0.01A, fixed
Resistance Limits = 0.0Ω-1.50Ω |
| 3870 | AC Hipot
DC Hipot
Ground Continuity
Insulation Resistance | AC Hipot
Voltage Output = 0-5000VAC
Leakage Current Limits = 0.00-20.0mA
Output Frequency = 50/60Hz
DC Hipot
Voltage Output = 0-6000VDC
Leakage Current Limits = 1µA-7.500mA
DC Ripple ≤ 5% Ripple RMS at 6KVDC @ 7.5mA, Resistive Load
Ground Continuity
Current = DC 0.1A ± 0.01A, fixed
Resistance Limits = 0.0Ω-1.50Ω
Insulation Resistance
Voltage Output = 30-1000VDC
Resistance Range = 1MΩ-50GΩ |