Configured models contain the following attributes:
Please use 'Get Quick Quote' and we’ll contact you and quote for your exact need.
You can also get in touch, if you prefer, and our experts will be able to guide you with the right application and procurement solution for this product.
Please refer to the Resources section for Datasheets or see the Product Overview.
If you would like to know more, please get in touch and one of our team will be happy to help.
The S930907B spectrum analysis (SA) adds high-performance microwave spectrum analysis to the N522xB/N524xB PNA family up to 67 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.
It is recommended to use this option with PNA (N522xB) or PNA-X (N524xB) models with internal receiver attenuators to avoid receiver compression when measuring large signals. The upper frequency range of the SA application is determined by the installed SA license or the stop frequency of the instrument, whichever is smaller.
The PNA SA application adds NPR measurement to the PNA family. It provides integrated measurement setup including multitone signal generation with vector signal generator. New coherent-measurement and vector-averaging techniques employed in the PNA SA application allow you to make faster and more accurate NPR and ACPR measurements with better dynamic range than the conventional NPR measurement with spectrum analyzer.
Key Features |
High-performance spectrum analysis up to 67 GHz on N522xB/N523xB/N524xB PNA series network analyzers |
Fast spurious searches |
A multi-channel SA with internal swept-signal generators |
In-fixture spectrum measurements using VNA calibration |
Fast band-/noise-power measurements |
Fast and accurate Noise Power Ratio (NPR) measurement with low IMD noise floor |
Specifications | ||
Application Software⁸ | ||
Software Overview | ||
Application Software⁸ | Description | Additional Information |
S93007B | Automatic fixture removal | -- |
S93010B | Time domain analysis | -- |
S93011B | Enhanced Time Domain Analysis with TDR | Provides TDR measurement class. S93010B is a subset of S93011B. |
S93015B | Real time S-parameter and power measurement uncertainty | Displays the measurement uncertainty dynamically (real-time) on the measurement trace |
S93025B | Basic pulsed-RF measurements | Includes control of internal pulse generators and provides pulse widths to 200 ns using wideband detection |
S93026B | Advanced pulsed-RF measurements | Includes control of internal pulse generators and provides pulse widths to 100 ns using wideband detection, and 20 ns using narrowband detection. |
S93027B⁸ | Add mechanical noise tuner control for noise figure/ parameter measurements | Provides ability to control Maury Microwave's LXI impedance tuners. Requires application software S93029B |
S93029B | Noise figure measurements with vector correction² | Standard receivers are used if hardware option N524xB-029 is not present |
S930317B | Phase noise measurement up to 70 GHz | Direct Digital Synthesizer (DDS) source is required. (S/N prefix 6021 or after, or upgraded unit with N52xxBU-2S7 or 4S7) |
S930321B | Phase noise measurement up to 125 GHz | This is for N5290A/91A or N5292A with N5293AX/95AX frequency extenders configuration. Direct Digital Synthesizer (DDS) source is required on PNA/ PNA-X (S/N prefix 6021 or after, or upgraded unit with N52xxBU-2S7 or 4S7) |
S930700B⁸ | Modulation distortion, up to 8.5 GHz | Requires test set option 22x or 42x |
S930701B⁸ | Modulation distortion, up to 13.5 GHz | Requires test set option 22x or 42x |
S930702B⁸ | Modulation distortion, up to 26.5 GHz | Requires test set option 22x or 42x |
S930704B⁸ | Modulation distortion, up to 43.5 GHz | Requires test set option 22x or 42x |
S930705B⁸ | Modulation distortion, up to 50 GHz | Requires test set option 22x or 42x |
S930707B⁸ | Modulation distortion, up to 70 GHz | Requires test set option 22x or 42x |
S93080B | Frequency-offset measurements | Provides ability to independently set the frequency of internal sources and receivers, and to configure external sources. This functionality is included withS93029/082/083/084/086/087/089/090x/093/094B |
S93082B | Scalar mixer/converter measurements | Provides SMC measurement class. S93082B is a subset of S93083B. |
S93083B | Vector and scalar mixer/converter measurements³ | Provides SMC+Phase and VMC measurement classes |
S93084B | Embedded-LO capability | Works with S93029/082/083/086/087B |
S93086B | Gain-compression measurements | -- |
S93087B | Intermodulation distortion measurements⁴ | -- |
S93088B | Source phase control | -- |
S93089B | Differential and I/Q device measurements | Requires a 4-port test set option (4xx) |
S930900B | Spectrum analysis, up to 8.5 GHz⁵ | -- |
S930901B | Spectrum analysis, up to 13.5 GHz⁵ | -- |
S930902B | Spectrum analysis, up to 26.5 GHz ⁵ | -- |
S930904B | Spectrum analysis, up to 43.5 GHz⁵ | -- |
S930905B | Spectrum analysis, up to 50 GHz⁵ | -- |
S930907B | Spectrum analysis, up to 70 GHz⁵ | -- |
S930909B | Spectrum analysis, up to 90 GHz⁵ | -- |
S93093B | Spectrum analysis, up to 120 GHz | -- |
S93094B | Spectrum analysis, beyond 120 GHz | -- |
S93110B⁸ | Active hot parameters | Export-controlled |
S93111B⁸ | Active hot parameters | Function-restricted version. The maximum operation is 50 GHz with N5247B |
S93118B | Fast CW measurements | -- |
S93460B | True-mode stimulus | Requires a 4-port test set option (4xx) |
S93551B | N-port measurements⁶ ⁷ | -- |
S94601B | Device measurement expert (DMX) | -- |
S94602B | Limit assistant | -- |
Note:
¹ Supported software license types: fixed-perpetual (1FP), transportable-perpetual (1TP), fixed-1-year (1FY), and transportable1-year (1TY) (note: S93093B, S93094B, S93898B, and S94510B have fixed-license types only).
² For N522xB and N5241/42/49B, vector-noise-corrected measurements require an ECal for use as an impedance tuner. For N5244/45/47B with Option 029, an internal tuner is included. Noise calibration requires a power meter when using a standard receiver. When using the low-noise receiver (Option 029), either a power meter or a 346-series noise source is required (Keysight 346C or 346C-K01 recommended). A power meter is required for measuring mixers and converters.
³ A configurable test set is required for VMC measurements to connect a reference mixer, or for SMC+Phase measurements using the comb-generator-based calibration. When ordered with PNA test set Options 200, 210, 400, or 410 (no front-panel jumpers), phase and delay measurements can only by done using SMC+Phase with a calibration mixer.
⁴ S93087B can be used without PNA-X Options 22x or 42x, but external equipment such as a signal generator and a combiner may be required.
⁵ A test set with internal receiver attenuators is recommended to avoid receiver compression when measuring large input signals.
⁶ When ordering a test set, select an appropriate interface kit.
⁷ When configured as a multiport analyzer using S93551B and a multiport test set, the combiner feature of Option 22x or 42x is temporarily disabled. When configured as a standalone analyzer, the combiner feature is enabled.
⁸ PNA-X models only.