Differential signaling used in high speed serial standards requires very accurate characterization. The industry-leading bandwidth and signal fidelity found in a Tektronix low voltage differential oscilloscope probe ensures that you see every possible detail. Tektronix offers TriMode™ architecture which streamlines measurement acquisition by enabling you to make differential, single-ended, and common mode measurements with a single connection!
The TDP7700 Series TriMode probes provide the highest probe fidelity available for real-time oscilloscopes. In addition, with connectivity innovations such as solder down tips with the probe’s input buffer mounted only a few millimeters from the end of the tip, the TDP7700 series probes provide unmatched usability for connecting to today’s most challenging electronic designs.
Key Features |
|
High Bandwidth for Signal Fidelity | TDP7710: 10 GHz
TDP7708: 8 GHz
TDP7706: 6 GHz
TDP7704: 4 GHz
|
Minimal Device Impact | Thin and flexible solder tips
Lightweight and flexible probe cable
Active buffer tip design for low probe loading
|
Easy to Connect TekFlex™ Connector Technology | Pinch-to-Open accessory connector
Versatile Connectivity - solder down tips, optional browser for handheld or fixtured probing, and coaxial input (SMA adapter)
Cross compatibility with P7700 series tip accessories
Full Bandwidth to 10 GHz
Probe cable and solder down tips operate over an extended temperature range
|
Probe and Tip Specific S-Parameters | Full AC calibration of the probe and tip's signal path based upon unique s-parameter models
Unique DSP filters created for each probe and tip
|
FlexChannel® Interface for Oscilloscope/Probe Control and Usability | Direct control via probe buttons or from the oscilloscope's menus
Automated control of probe settings via the oscilloscope
Automatic recognition of the probe and tip when attached to the oscilloscope
|
Specifications |
|
TDP7000 Series
TriMode Probes
|
|
Features | Parameters |
Bandwidth (typical) |
|
TDP7704
TDP7706
TDP7708
TDP7710
| 4 GHz
6 GHz
8 GHz
10 GHz
|
Operating Voltage Window, A and B Inputs | ±4 V (2.92 tip)
±5.25 V (active tip)
±10 V (browser tip)
|
Differential Input Range | ±2V (2.92 tip)
±5V (active tip)
±12V (browser tip)
|
DC Input Resistance (differential) | 50 Ω (P77C292MM tip)
100k Ω (active tips)
144k Ω (browser tip)
|
DC Accuracy | ±2% |
TriMode Functionality | Yes
Differential only (browser tip)
|
Specifications |
|
TDP7000 Series
TriMode Probes
|
|
Model Overview |
|
Model | Description |
TDP7710 | 10 GHz TriMode probe with TekFlex connector technology |
TDP7708 | 8 GHz TriMode probe with TekFlex connector technology |
TDP7706 | 6 GHz TriMode probe with TekFlex connector technology |
TDP7704 | 4 GHz TriMode probe with TekFlex connector technology |