The ZV-Z2xx calibration kit contains precision standards for system error corrections with vector network analyzers. Both, male and female standards are included, by which insertable and non-insertable calibration is supported. Each kit comes with individual characterization data by means of S-parameters ("data based"), enabling excellent measurement accuracy. Along with open, short, match in male/female each, through standards (m-m, f-f, m-f); a torque wrench, counterholder and USB stick are also included.
Key Features |
Optimized mechanical stability and reproducibility |
Extended frequency ranges DC up to 24 GHz |
Open, short, match, through, male and female each |
Includes torque wrench and counterholder |
High-end accuracy with individual data-based characterization |
Benefits |
|
Data Based Characterization | Each calibration kit is individually characterized and comes with a customized S-parameters set, supporting the most accurate characterization and highly accurate VNA calibration. |
Ready For ZNA-K50(P) Measurement Uncertainty Analysis Option | Besides the S-parameter characterization data, the uncertainty data of the characterization are delivered by default.
This enables the ZN-Z2xx calibration kits to be used for an uncertainty analysis using option ZNA-K50(P)
|
Specifications |
|
ZV-Z2xx
Calibration Kits
|
|
Model Overview |
|
Features | Parameters |
Operating Temperature Range* | +18 °C to +28 °C |
Permissible Temperature Range* | 0 °C to +50 °C |
Storage Temperature Range* | –40 °C to +70 °C |
Dimensions (W x H x D) | 400 mm × 70 mm × 260 mm
(15.8 in × 2.8 in × 10.2 in)
|
Weight | ZV-Z270: 1800 g (4 lb)
ZV-Z235: 1400 g (3 lb)
ZV-Z235E: 1400 g (3 lb)
ZV-Z229: 1400 g (3 lb)
ZV-Z224: 1400 g (3 lb)
ZV-Z218: 1400 g (3 lb)
ZV-Z210: 1400 g (3 lb)
Shipping Weight: 4 kg (9 lb)
|
Note:
* in line with IEC 60068-2-1 and IEC 60068-2-2
Specifications |
|
|
|
|
|
ZV-Z2xx
Calibration Kits
|
|
|
|
|
|
Model Overview |
|
|
|
|
|
Model | Order Number | Description | Connector | Impedance | Frequency Range |
ZV-Z270 | 5011.6536.02 | Calibration Kit | type N female and male | 50 Ω | 0 Hz to 18 GHz |
ZV-Z235 | 5011.6542.02 | Calibration Kit | 3.5 mm female and male | 50 Ω | 0 Hz to 24 GHz |
ZV-Z235E | 5011.6707.02 | Calibration Kit | 3.5 mm female and male | 50 Ω | 0 Hz to 33 GHz |
ZV-Z229 | 5011.6559.02 | Calibration Kit | 2.92 mm female and male | 50 Ω | 0 Hz to 40 GHz |
ZV-Z224 | 5011.6565.02 | Calibration Kit | 2.4 mm female and male | 50 Ω | 0 Hz to 50 GHz |
ZV-Z218 | 5011.6571.02 | Calibration Kit | 1.85 mm female and male | 50 Ω | 0 Hz to 67 GHz |
ZV-Z210 | 5011.6588.02 | Calibration Kit | 1.0 mm female and male | 50 Ω | 0 Hz to 110 GHz |