N5262BWxx transceiver modules have both a source and measurement receiver and can be used with the network analyzer to make S-parameter reflection measurements. Another transceiver or receiver module is required to make transmission measurements. Transceiver modules are also known as transmission/reflection modules.
Specifications |
|
|
|
|
|
|
|
|
|
Keysight N5262BW08 |
|
|
|
|
|
|
|
|
|
VDI frequency extenders |
|
|
|
|
| 522xB PNA / N524xB PNA-X withN5262BWxx |
|
|
|
Wavegude Band | Frequency Coverage (GHz) Standard | Frequency Coverage (GHz) Extended2 | Test Port Power (dBm typical) | Limit (estimate, dBm, damage) TxRx, TxRef | Directivity (dB) | Dynamic range (BW = 10 Hz,dB) Typical | Dynamic range (BW = 10 Hz,dB) Minimum | Stability Magnitude (± dB) | Stavility Phase (± deg) |
WR15 | 50-75 | 47-77 | 13 | 30 | 30 | 120 | 110 | 0.1 | 1.5 |
WR15-P | 50-75 |
| 13 | 30 | 30 |
|
|
|
|
WR12 | 60-90 | 55-95 | 18 | 30 | 30 | 120 | 110 | 0.1 | 1.5 |
WR12 SE Option | 60-90 | 55-90 | 13 | 30 | 30 | 120 | 110 | 0.1 | 1.5 |
WR12-P | 60-90 |
| 13 | 30 | 30 |
|
|
|
|
WR10 | 75-110 | 67-115 | 18 | 30 | 30 | 120 | 110 | 0.1 | 1.5 |
WR10 SE Option | 75-110 | 67-110 | -1 | 20 | 30 | 120 | 110 | 0.1 | 1.5 |
WR10-P | 75-110 |
| 13 | 20 | 30 |
|
|
|
|
WR10-P SE Option | 75-110 |
| -1 | 20 | 30 |
|
|
|
|
WR8.0 | 90-140 |
| 16 | 30 | 30 | 120 | 110 | 0.15 | 2 |
WR6.5 | 110-170 |
| 13 | 30 | 30 | 120 | 110 | 0.25 | 4 |
WR6.5-P | 110-170 |
| 13 | 30 | 30 |
|
|
|
|
WR5.1 | 140-220 |
| 6 | 30 | 30 | 120 | 110 | 0.25 | 4 |
WR4.3 | 170-260 |
| 4 | 28 | 30 | 115 | 110 | 0 | 4 |
WR3.4 | 220-330 |
| 1 | 26 | 30 | 115 | 105 | 0.3 | 6 |
Specifications |
|
|
|
|
|
|
|
|
Keysight N5262BW08 |
|
|
|
|
|
|
|
|
OML Frequency Extenders |
|
|
|
| N522xB PNA / N524xB PNA-X withN5256A/BWxx |
|
|
|
Wavegude Band | Frequency Coverage (GHz) Standard | Test Port Power (dBm typical) | Limit (estimate, dBm, damage) TxRx, TxRef | Directivity (dB) | Dynamic range Typical | Dynamic range Minimum | Stability Magnitude (± dB) | Stability Phase (± deg) |
WR15 | 50-75 | 8 | 20 | 35 | 105 | 92 | 0.2 | 2 |
WR12 | 60-90 | 5 | 20 | 35 | 105 | 92 | 0.2 | 2 |
WR10 | 75-110 | 5 | 20 | 35 | 110 | 95 | 0.2 | 2 |
WR8.0 | 90-140 | 4 | 20 | 33 | 105 | 90 | 0.3 | 3 |
WR6.5 | 110-170 | -10 | 20 | 30 | 95 | 80 | 0.4 | 5 |
WR5.1 | 140-220 | -13 | 13 | 30 | 95 | 80 | 0.4 | 6 |
WR3.4 | 220-325 | -23 | 13 | 30 | 75 | 60 | 0.4 | 8 |