Quality decisions are based on clear understandable facts. When it’s your job to budget and control costs you need the tools that help you see into the future. Building a system to proactively forecast and mitigate maintenance costs is one of a plant’s best options for increasing its total profitability. That is why seasoned thermographers, operations managers and reliability engineers turn to Fluke articulating thermal cameras. The ergonomic design and neck strap make long inspection days easier. Outside the rotating screen lets you adjust to minimize glare and the touchscreen delivers a premium in-field viewing experience. The Fluke TiX501 infrared camera comes with 640 x 480 resolution and temperature measurements up to 650 °C.
In focus images are easier to capture with LaserSharp autofocus and 2x digital zoom. Images can be optimized on the large screen right in the field. And with the 240°articulation, you can collect the images needed, whether they are overhead, around corners or under equipment. You have the tool you need to take quality images, near or far. When the job requires a level of precision well beyond the ordinary you need a remarkable camera – the Fluke TiX501.
Get the most out of your TiX501 with Fluke Connect™ desktop software. Create professional reports in minutes while efficiently capturing full radiometric data to support your maintenance program.
Key Features |
In-focus images in a matter of seconds. LaserSharp™ Auto Focus uses a built-in laser distance meter that calculates and displays the distance from your designated target and immediately adjusts the focus. |
Shoot images near…and far. Interchangeable Smart Lenses require no calibration and give you the versatility and image quality needed to conduct inspections in almost any environment. |
Simply the best optics to transmit energy and produce high quality infrared images. Fluke uses only 100 % diamond-turned germanium lenses with specialty coatings. |
See more details when you adjust the level of infrared and visible light with patented IR-Fusion™ technology. |
Edit and analyze images on camera—edit emissivity, enable color alarms and markers, and adjust IR-Fusion™ visual and infrared image blending. |
Manage data, capture multiple measurements (mechanical, electrical and thermal) and organize them by piece of equipment with Fluke Connect™ software. |
Inspect multiple complex targets or targets from varying distances. Capture a clear, accurate image focused throughout the field of view with MultiSharp™ Focus. The camera automatically processes a stack of images focused near and far with the Ti480 PRO and TiX580. |
Applications |
Industrial maintenance inspections |
Predictive maintenance programs |
Oil and gas maintenance |
Utilities |
Specifications | ||||
Infrared Cameras | ||||
Model Overview | ||||
Model | Ti401 PRO | Ti480 PRO | TiX501 | TiX580 |
Color alarms (temperature alarms) | High temperature, low temperature, and isotherms (within range) | High temperature, low temperature, and isotherms (within range) | High temperature, low temperature, and isotherms (within range) | High temperature, low temperature, and isotherms (within range) |
Infrared spectral band | 7.5 μm to 14 μm (long wave) | 7.5 μm to 14 μm (long wave) | 7.5 μm to 14 μm (long wave) | 7.5 μm to 14 μm (long wave) |
Operating Temperature | -10 °C to +50 °C (14 °F to 122 °F) | -10 °C to +50 °C (14 °F to 122 °F) | -10 °C to +50 °C (14 °F to 122 °F) | -10 °C to +50 °C (14 °F to 122 °F) |
Storage Temperature | -20 °C to +50 °C (-4 °F to 122 °F) without batteries | -20 °C to +50 °C (-4 °F to 122 °F) without batteries | -20 °C to +50 °C (-4 °F to 122 °F) without batteries | -20 °C to +50 °C (-4 °F to 122 °F) without batteries |
Relative humidity | 10 % to 95 % non-condensing | 10 % to 95 % non-condensing | 10 % to 95 % non-condensing | 10 % to 95 % non-condensing |
Center-point temperature measurement | Yes | Yes | Yes | Yes |
Spot temperature | Hot and cold spot markers | Hot and cold spot markers | Hot and cold spot markers, individually enabled | Hot and cold spot markers, individually enabled |
User-definable spot markers | No | 3 user-definable spot markers | 2 user-definable spot markers | 3 user-definable spot markers |
User defined measurement boxes | 1 expandable-contractible measurement box with MIN-MAX-AVG temp display | Up to 3 expandable contractible measurement box with MIN-MAX-AVG temp display | 1 expandable-contractible measurement box with MIN-MAX-AVG temp display | 3-Expandable-contractible measurement box with MIN-MAX-AVG temp display |
Hard Case | Rugged, hard carrying case; soft transport bag | Rugged, IP67 rated, airtight hard case with custom foam insert | Rugged, IP67 rated, airtight hard case with custom foam insert | Rugged, IP67 rated, airtight hard case with custom foam insert |
Safety | IEC 61010-1: Overvoltage category II, Pollution Degree 2 | IEC 61010-1: Overvoltage category II, Pollution Degree 2 | IEC 61010-1: Overvoltage category II, Pollution Degree 2 | IEC 61010-1: Overvoltage category II, Pollution Degree 2 |
Electromagnetic compatibility | IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A | IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A | IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A | IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A |
Australian RCM | IEC 61326-1 | IEC 61326-1 | IEC 61326-1 | IEC 61326-1 |
US FCC | CFR 47, Part 15 Subpart B | CFR 47, Part 15 Subpart B | CFR 47, Part 15 Subpart B | CFR 47, Part 15 Subpart B |
Vibration | 0.03 g2/Hz (3.8 g), 2.5 g IEC 60068-2-6 | 0.03 g2/Hz (3.8 g), 2.5 g IEC 60068-2-6 | 0.03 g2/Hz (3.8 g), 2.5 g IEC 60068-2-6 | 0.03 g2/Hz (3.8 g), 2.5 g IEC 60068-2-6 |
Shock | 25 g, IEC 68-2-29 | 25 g, IEC 68-2-29 | 25 g, IEC 68-2-29 | 25 g, IEC 68-2-29 |
Drop | Engineered to withstand 2 meter (6.5 feet) drop with standard lens | Engineered to withstand 2 meter (6.5 feet) drop with standard lens | Engineered to withstand 1 meter (3.3 feet) drop with standard lens | Engineered to withstand 1 meter (3.3 feet) drop with standard lens |
Size (H x W x L) | 27.7 cm x 12.2 cm x 16.7 cm (10.9 in x 4.8 in x 6.5 in) | 27.7 cm x 12.2 cm x 16.7 cm (10.9 in x 4.8 in x 6.5 in) | 27.3 cm x 15.9 cm x 9.7 cm (10.8 in x 6.3 in x 3.8 in) | 27.3 cm x 15.9 cm x 9.7 cm (10.8 in x 6.3 in x 3.8 in) |
Weight (battery included) | 1.04 kg (2.3 lb) | 1.04 kg (2.3 lb) | 1.54 kg (3.4 lb) | 1.54 kg (3.4 lb) |
Enclosure rating | IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions) | IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions) | IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions) | IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty | Two-years (standard), extended warranties are available | Two-years (standard), extended warranties are available | Two-years (standard), extended warranties are available | Two-years (standard), extended warranties are available |
Recommended calibration cycle | Two-years (assumes normal operation and normal aging | Two-years (assumes normal operation and normal aging | Two-years (assumes normal operation and normal aging | Two-years (assumes normal operation and normal aging |
Frame Rate | 60 Hz or 9 Hz versions | 60 Hz or 9 Hz versions | 60 Hz or 9 Hz versions | 60 Hz or 9 Hz versions |