You are browsing the LATIN_EN site. Would you like to be redirected to another country or region to see content and products specific to your location?
US
Configured models contain the following attributes:
ThermalTemperature Measurement & EnvironmentalInspection Equipment - Cameras and BorescopesPlease use 'Get Quick Quote' and we’ll contact you and quote for your exact need.
You can also get in touch, if you prefer, and our experts will be able to guide you with the right application and procurement solution for this product.
Please refer to the Resources section for Datasheets or see the Product Overview.
If you would like to know more, please get in touch and one of our team will be happy to help.
infrared camera featuring a 680 x 480 resolution and superior image quality. Versatile and easy to use, this camera comes with an articulating touchscreen that rotates 240° and offers a temperature range up to 1832°F (1000°C).
Key Features |
In-focus images in a matter of seconds. LaserSharp™ Auto Focus uses a built-in laser distance meter that calculates and displays the distance from your designated target and immediately adjusts the focus |
Shoot images near…and far. Interchangeable Smart Lenses require no calibration and give you the versatility and image quality needed to conduct inspections in almost any environment |
Optics to transmit energy and produce high quality infrared images. Fluke uses only 100% diamond-turned germanium lenses with specialty coatings |
See more details when you adjust the level of infrared and visible light with patented IR-Fusion™ technology |
Edit and analyze images on camera—edit emissivity, enable color alarms and markers, and adjust IR-Fusion™ visual and infrared image blending |
Manage data, capture multiple measurements (mechanical, electrical and thermal) and organize them by piece of equipment with Fluke Connect™ software |
Inspect multiple complex targets or targets from varying distances |
Capture a clear, accurate image focused throughout the field of view with MultiSharp™ Focus |
Automatically processes a stack of images focused near and far |
Rugged, superbly engineered 640 x 480 thermal imaging camera |
Provides large 5.7" (144.78 mm) responsive LCD touchscreen with 150% more viewing area than 3.5" (88.9 mm) screen |
Features 240° rotating screen for unmatched shooting flexibility |
Provides 4x the pixel data with on-camera SuperResolution to create a 1280 x 960 resolution image |
Real-time temperature graphs |
Radiometric video recording |
Auto capture image sequence |
MatLab and LabView integration capabilities |
Applications |
Industrial maintenance |
Oil and gas predictive maintenance |
Power generation/transmission |
Research and development - electrical, mechanical, and sciences |
Quality control |
Electrical inspections |
HVAC/R inspections |
Mechanical |
Residential home inspections |
Light commercial maintenance |
Building diagnostics - building envelope and commercial/industrial facilities |
Heavy commercial facility maintenance |
Veterinary |
Reliability inspections (PdM) |
Heavy building diagnostics - building envelope and construction defects |
Electrical, water, gas utilities |
Chemical processing |
Machinery, instrumentation and appliances |
Specifications | ||||
Infrared Cameras | ||||
Model Overview | ||||
Model | Ti401 PRO | Ti480 PRO | TiX501 | TiX580 |
Color alarms (temperature alarms) | High temperature, low temperature, and isotherms (within range) | High temperature, low temperature, and isotherms (within range) | High temperature, low temperature, and isotherms (within range) | High temperature, low temperature, and isotherms (within range) |
Infrared spectral band | 7.5 μm to 14 μm (long wave) | 7.5 μm to 14 μm (long wave) | 7.5 μm to 14 μm (long wave) | 7.5 μm to 14 μm (long wave) |
Operating Temperature | -10 °C to +50 °C (14 °F to 122 °F) | -10 °C to +50 °C (14 °F to 122 °F) | -10 °C to +50 °C (14 °F to 122 °F) | -10 °C to +50 °C (14 °F to 122 °F) |
Storage Temperature | -20 °C to +50 °C (-4 °F to 122 °F) without batteries | -20 °C to +50 °C (-4 °F to 122 °F) without batteries | -20 °C to +50 °C (-4 °F to 122 °F) without batteries | -20 °C to +50 °C (-4 °F to 122 °F) without batteries |
Relative humidity | 10 % to 95 % non-condensing | 10 % to 95 % non-condensing | 10 % to 95 % non-condensing | 10 % to 95 % non-condensing |
Center-point temperature measurement | Yes | Yes | Yes | Yes |
Spot temperature | Hot and cold spot markers | Hot and cold spot markers | Hot and cold spot markers, individually enabled | Hot and cold spot markers, individually enabled |
User-definable spot markers | No | 3 user-definable spot markers | 2 user-definable spot markers | 3 user-definable spot markers |
User defined measurement boxes | 1 expandable-contractible measurement box with MIN-MAX-AVG temp display | Up to 3 expandable contractible measurement box with MIN-MAX-AVG temp display | 1 expandable-contractible measurement box with MIN-MAX-AVG temp display | 3-Expandable-contractible measurement box with MIN-MAX-AVG temp display |
Hard Case | Rugged, hard carrying case; soft transport bag | Rugged, IP67 rated, airtight hard case with custom foam insert | Rugged, IP67 rated, airtight hard case with custom foam insert | Rugged, IP67 rated, airtight hard case with custom foam insert |
Safety | IEC 61010-1: Overvoltage category II, Pollution Degree 2 | IEC 61010-1: Overvoltage category II, Pollution Degree 2 | IEC 61010-1: Overvoltage category II, Pollution Degree 2 | IEC 61010-1: Overvoltage category II, Pollution Degree 2 |
Electromagnetic compatibility | IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A | IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A | IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A | IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A |
Australian RCM | IEC 61326-1 | IEC 61326-1 | IEC 61326-1 | IEC 61326-1 |
US FCC | CFR 47, Part 15 Subpart B | CFR 47, Part 15 Subpart B | CFR 47, Part 15 Subpart B | CFR 47, Part 15 Subpart B |
Vibration | 0.03 g2/Hz (3.8 g), 2.5 g IEC 60068-2-6 | 0.03 g2/Hz (3.8 g), 2.5 g IEC 60068-2-6 | 0.03 g2/Hz (3.8 g), 2.5 g IEC 60068-2-6 | 0.03 g2/Hz (3.8 g), 2.5 g IEC 60068-2-6 |
Shock | 25 g, IEC 68-2-29 | 25 g, IEC 68-2-29 | 25 g, IEC 68-2-29 | 25 g, IEC 68-2-29 |
Drop | Engineered to withstand 2 meter (6.5 feet) drop with standard lens | Engineered to withstand 2 meter (6.5 feet) drop with standard lens | Engineered to withstand 1 meter (3.3 feet) drop with standard lens | Engineered to withstand 1 meter (3.3 feet) drop with standard lens |
Size (H x W x L) | 27.7 cm x 12.2 cm x 16.7 cm (10.9 in x 4.8 in x 6.5 in) | 27.7 cm x 12.2 cm x 16.7 cm (10.9 in x 4.8 in x 6.5 in) | 27.3 cm x 15.9 cm x 9.7 cm (10.8 in x 6.3 in x 3.8 in) | 27.3 cm x 15.9 cm x 9.7 cm (10.8 in x 6.3 in x 3.8 in) |
Weight (battery included) | 1.04 kg (2.3 lb) | 1.04 kg (2.3 lb) | 1.54 kg (3.4 lb) | 1.54 kg (3.4 lb) |
Enclosure rating | IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions) | IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions) | IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions) | IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty | Two-years (standard), extended warranties are available | Two-years (standard), extended warranties are available | Two-years (standard), extended warranties are available | Two-years (standard), extended warranties are available |
Recommended calibration cycle | Two-years (assumes normal operation and normal aging | Two-years (assumes normal operation and normal aging | Two-years (assumes normal operation and normal aging | Two-years (assumes normal operation and normal aging |
Frame rate | 60 Hz or 9 Hz versions | 60 Hz or 9 Hz versions | 60 Hz or 9 Hz versions | 60 Hz or 9 Hz versions |