Network & Fiber InstallationsOptical Time Domain ReflectometersThe only fully automated, always-connected solution natively combining bidirectional OLTS and OTDR-ready capabilities on one compact device. Supports simplex, duplex and multi-fiber connectors up to 24 fibers.
The FTB Lite 975 supports evolving data center and AI infrastructure with a flexible design for test cords that streamlines certification across simplex, duplex, and base‑8/12/16/24 multi‑fiber cables with multiple connector types (MPO/MMC/LC).
| KEY FEATURES |
| Native simplex, duplex and multi-fiber testing up to 24 fibers |
| Bidirectional Tier-1 OLTS-enabled testing: insertion loss (IL), optical return loss (ORL), fiber length measurements, and polarity validation |
| Fault-finding and OTDR capabilities for fiber characterization with EXFO’s intelligent Optical Link Mapper (iOLM) |
| End-to-end automation from one-touch referencing, touchless testing through reporting to OTDR-enabled troubleshooting. |
| SmartRef™: One-touch referencing, validation and troubleshooting with visual diagnostics |
| APPLICATIONS |
| Intra data center |
| Campus data center interconnect (DCI) |
| Metro/longhaul DCI |
| Telco and FTTx |
| SPECIFICATIONS | |
| Model: FTB Lite 975 | |
| Feature | Parameter |
| Automation | Yes |
| Calibrated Wavelengths | 1550 / 1625 / 1310 |
| EXFO Exchange Compatibility | Yes |
| Fiber Connector Type | Duplex / Simplex / Multi-fiber |
| Fiber Type | Singlemode |
| Measurement Type | Optical return loss (ORL) / Insertion loss / Polarity / Length / OTDR (upcoming) |
| Multiple Wavelength Measuring | Yes |
| Visual Fault Locator (VFL) | Yes |
| SPECIFICATIONS | |
| FTB-Lite-975 Overview | |
| Model FTB-Lite-975 | |
| Optical Configuration (FTB-Lite-975-XX) | |
| SM1-DF | SM simplex/duplex fiber, 1310/1550 nm |
| SM3-DF | SM simplex/duplex fiber, 1310/1550/1625 nm |
| SM1-MF24 | SM simplex/duplex/multifiber 24, 1310/1550 nm |
| Base Hardware (FTB-Lite-975-XX-XX) | |
| OLTS | OLTS capabilities |
| iOLMC | OTDR-based capabilities (iOLM), including OLTS capabilities |
| Power Meter and VF (FTB-Lite-975-XX-XX-XX) | |
| 00 | Without power meter or VFL |
| VFL | Visual fault locator |
| VFLHP | High power VFL |
| VPM2X | VFL and power meter; GeX detector |
| VPM2XHP | High-power VFL and power meter; GeX detector |
| Connectivity (FTB-Lite-975-XX-XX-XX-XX) | |
| FRF | With full RF capability (LTE, GNSS, Wi-Fi and Bluetooth) |
| Multi-fiber Test Cord (FTB-Lite-975-XX-XX-XX-XX-XX) | |
| MC-MF24-SM-92F12 | SM MPO-12/APC unpinned (female), 25 m |
| MC-MF24-SM-92M12 | SM MPO-12/APC pinned (male), 25 m |
| MC-MF24-SM-92F16 | SM MPO-16/APC unpinned (female), 25 m |
| MC-MF24-SM-92M16 | SM MPO-16/APC pinned (male), 25 m |
| MC-MF24-SM-92F24 | SM MPO-24/APC unpinned (female), 25 m |
| MC-MF24-SM-92M24 | SM MPO-24/APC pinned (male), 25 m |
| MC-MF24-SM-116F16 | SM MMC-16/APC unpinned (female), 25 m |
| MC-MF24-SM-116M16 | SM MMC-16/APC pinned (male), 25 m |
| MC-MF24-SM-116F24 | SM MMC-24/APC unpinned (female), 25 m |
| MC-MF24-SM-116M24 | SM MMC-24/APC pinned (male), 25 m |
| Duplex-fiber Test Cord (FTB-Lite-975-XX-XX-XX-XX-XX-XX) | |
| DC-SM-SCA-SCA-25 | SM duplex SC/APC, 25 m |
| DC-SM-SCA-SCU-25 | SM duplex SC/UPC, 25 m |
| DC-SM-SCA-LCA-25 | SM duplex LC/APC, 25 m |
| DC-SM-SCA-LCU-25 | SM duplex LC/UPC, 25 m |
| DC-SM-SCA-MDCA-25 | SM duplex MDC/APC, 25 m |
| DC-SM-SCA-MDCU-25 | SM duplex MDC/UPC, 25 m |
| Single-fiber Test Cord (FTB-Lite-975-XX-XX-XX-XX-XX-XX-XX) | |
| SC-SM-SCA-SCA-25 | SM SC/APC, 25 m |
| SC-SM-SCA-SCU-25 | SM SC/UPC, 25 m |
| SC-SM-SCA-LCA-25 | SM LC/APC, 25 m |
| SC-SM-SCA-LCU-25 | SM LC/UPC, 25 m |
| SC-SM-SCA-FCA-25 | SM FC/APC, 25 m |
| SC-SM-SCA-FCU-25 | SM FC/UPC, 25 m |