配置型號包含以下特性:
RF & Microwave PowerNoise & OtherRF Power Meters請參考資源中的資料文檔或查看產品總覽。
如果您想瞭解更多,請 聯繫,我們的團隊將為您提供幫助。
The Keysight U2067XA is a fast, accurate and wide dynamic range 10 MHz – 67 GHz USB peak and average power sensor.
Accurately measure any modulated signal with the Keysight Technologies, Inc. U/L2050/60 X-Series wide dynamic range power sensors. The USB/LAN connectivity models come with a wide dynamic range, covering -70 to +26 dBm. This sensor offers very accurate and repeatable power measurements for any modulated signal and comes with a super-fast measurement speed of 50,000 readings/sec, which enables higher manufacturing throughput. Users can also save time and reduce measurement uncertainty with the internal zero and calibration function. The U/L2050/60 X-Series is supported by the Keysight BenchVue software. BenchVue makes it easy to control your power meter to log data and visualize measurements in a wide array of display options without any programming. Simply connect the sensor to your PC installed BenchVue BV0007B Power Meter/Sensor Control and Analysis app to perform average power measurement and analysis.
Key Features |
Frequency range of 10 MHz – 67 GHz |
USB connectivity with a wide dynamic range of -70 to +20 dBm (frequency 10 MHz to 50 GHz) / -70 to +15 dBm (frequency > 50 GHz to 54 GHz) / -70 to +10 dBm (frequency > 54 GHz to 67 GHz) for small signal measurements |
5 MHz video bandwidth and single shot real-time capture at 20 Msample/sec per second |
Variable Sampling Rate 1M samples/sec and Long Memory 1M samples data storage |
Fast real-time measurement of 50,000 readings/sec |
Real-time measurement with zero dead time to ensure every single continuous pulse is measured |
Average mode time-selectivity function allows full dynamic range for average and time selectivity average power measurements |
Internal zero and automatic calibration saves time and reduces measurement uncertainty |
A BenchVue software license (BV0007B) is now included with your instrument. BenchVue makes it simple to connect, control instruments, and automate test sequences |
Specifications | |
LAN / USB Average Power Sensor | |
Model Overview | |
Model | Description |
U2049XA | LAN peak and average power sensor, 10 MHz to 33 GHz |
U2049XA, Option TVA | LAN peak and average power sensor, 10 MHz to 33 GHz, Thermal Vacuum Option |
U2051XA | USB wide dynamic range average power sensor, 10 MHz to 6 GHz |
U2052XA | USB wide dynamic range average power sensor, 10 MHz to 18 GHz |
U2053XA | USB wide dynamic range average power sensor, 10 MHz to 33 GHz |
U2054XA | USB wide dynamic range average power sensor, 10 MHz to 40 GHz |
U2055XA | USB wide dynamic range average power sensor, 10 MHz to 50 GHz |
U2055XA, Option 053 | USB wide dynamic range average power sensor, 10 MHz to 53 GHz |
U2056XA | USB wide dynamic range average power sensor, 10 MHz to 54 GHz |
U2057XA | USB wide dynamic range average power sensor, 10 MHz to 67 GHz |
U2061XA | USB wide dynamic range peak and average power sensor, 10 MHz to 6 GHz |
U2062XA | USB wide dynamic range peak and average power sensor, 10 MHz to 18 GHz |
U2063XA | USB wide dynamic range peak and average power sensor, 10 MHz to 33 GHz |
U2064XA | USB wide dynamic range peak and average power sensor, 10 MHz to 40 GHz |
U2065XA | USB wide dynamic range peak and average power sensor, 10 MHz to 50 GHz |
U2065XA, Option 053 | USB wide dynamic range peak and average power sensor, 10 MHz to 53 GHz |
U2066XA | USB wide dynamic range peak and average power sensor, 10 MHz to 54 GHz |
U2067XA | USB wide dynamic range peak and average power sensor, 10 MHz to 67 GHz |
Specifications | |
LAN Average Power Sensor | |
Model Overview | |
Model | Description |
L2051XA | LAN wide dynamic range average power sensor, 10 MHz to 6 GHz |
L2052XA | LAN wide dynamic range average power sensor, 10 MHz to 18 GHz |
L2053XA | LAN wide dynamic range average power sensor, 10 MHz to 33 GHz |
L2054XA | LAN wide dynamic range average power sensor, 10 MHz to 40 GHz |
L2055XA | LAN wide dynamic range average power sensor, 10 MHz to 50 GHz |
L2055XA, Option 053 | LAN wide dynamic range average power sensor, 10 MHz to 53 GHz |
L2056XA | LAN wide dynamic range average power sensor, 10 MHz to 54 GHz |
L2057XA | LAN wide dynamic range average power sensor, 10 MHz to 67 GHz |
L2061XA | LAN wide dynamic range peak and average power sensor, 10 MHz to 6 GHz |
L2062XA | LAN wide dynamic range peak and average power sensor, 10 MHz to 18 GHz |
L2063XA | LAN wide dynamic range peak and average power sensor, 10 MHz to 33 GHz |
L2064XA | LAN wide dynamic range peak and average power sensor, 10 MHz to 40 GHz |
L2065XA | LAN wide dynamic range peak and average power sensor, 10 MHz to 50 GHz |
L2065XA, Option 053 | LAN wide dynamic range peak and average power sensor, 10 MHz to 53 GHz |
L2066XA | LAN wide dynamic range peak and average power sensor, 10 MHz to 54 GHz |
L2067XA | LAN wide dynamic range peak and average power sensor, 10 MHz to 67 GHz |
L2065XT, Option 053 | LAN peak and average power sensor, 10 MHz to 53 GHz, Thermal Vacuum Compliance |
L2066XT | LAN peak and average power sensor, 10 MHz to 54 GHz, Thermal Vacuum Compliance |
L2067XT | LAN peak and average power sensor, 10 MHz to 67 GHz, Thermal Vacuum Compliance |