配置型號包含以下特性:
RF & Microwave Spectrum AnalyzersSpectrum Analyzers-Performance1GHz <= 10GHz10GHz <= 20GHz20GHz <= 50GHzDC <= 1kHzBenchtop| 特性 | 參數 |
|---|---|
| High Frequency (range) | 1GHz <= 10GHz |
| High Frequency (range) | 10GHz <= 20GHz |
| High Frequency (range) | 20GHz <= 50GHz |
| Low Frequency (range) | DC <= 1kHz |
| Form Factor | Benchtop |
The PXA N9030A provides frequency coverage up to 50 GHz and ensures present and future flexibility through optional measurement capabilities and hardware expandability. Through external mixing with Keysight or third-party harmonic mixers, the PXA can measure signals to 325 GHz and beyond. The PXA’s advanced performance, flexibility, capability and expandability enable you to address demanding applications in aerospace, defense, commercial communications and more.
PXA N9030A 提供高達 50 GHz 的頻率覆蓋範圍,並透過可選的測量功能和硬體可擴展性確保當前和未來的靈活性。透過使用是德科技或第三方諧波混頻器進行外部混頻,PXA 可以測量頻率高達 325 GHz 及以上的訊號。 PXA 的先進性能、靈活性、功能和可擴展性使您能夠滿足航空航太、國防、商業通訊等領域的高要求應用。
The PXA signal analyzer delivers exceptional performance that reduces measurement uncertainty and reveals new levels of signal detail, starting with up to 75 dB spurious-free dynamic range at the 140-MHz analysis bandwidth. Industry-leading specifications include –129 dBc/Hz phase noise (room temperature) at 10 kHz offset (1 GHz), ±0.19 dB absolute amplitude accuracy, and sensitivity of –172 dBm displayed average noise level (DANL) at 2 GHz (with preamplifier and Noise Floor Extension technology). Newly added to the X-Series signal analyzers is Option EDP (enhanced display package), which includes a spectrogram feature for analyzing time-variant signal spectrum.
PXA 訊號分析儀具有卓越的性能,可降低測量不確定性並揭示新水平的訊號細節,在 140 MHz 分析頻寬下具有高達 75 dB 的無雜訊動態範圍。業界領先的規格包括 10 kHz 偏移 (1 GHz) 時 –129 dBc/Hz 相位雜訊(室溫)、±0.19 dB 絕對振幅精度以及 2 GHz 時 –172 dBm 顯示平均雜訊電平 (DANL) 的靈敏度(使用前置放大器和本底噪聲擴展技術)。 X 系列訊號分析儀中新增了選項 EDP(增強型顯示包),其中包括用於分析時變訊號頻譜的頻譜圖功能。
立即前往挑選更多 : 頻譜分析儀
| Key Features |
| Drive your evolution in the demanding applications of aerospace, defense & commercial communications with 160 MHz analysis bandwidth & industry-leading performance |
| Extend frequency up to 110 GHz with Keysight smart mixers; to THz with others |
| Capture transient or intermittent signals with real-time spectrum analysis |
| Simplify application-specific testing with X-Series apps: phase noise, noise figure, LTE-Advanced, WLAN & more |
| Perform deeper troubleshooting with the 89600 VSA software |
| Specifications | |
| PXA Series Signal and Spectrum Analyzer | |
| Features | Parameters |
| DANL @1 GHz | -171 dBm |
| Performance Level | ◆◆◆◆◆◇ |
| Applications-Cellular | 1xEV-DO cdma2000 cdmaOne GSM/EDGE/EDGE Evolution iDEN/WiDEN/MotoTalk TD-SCDMA with HSDPA/HSUPA/8PSK LTE/LTE-Advanced W-CDMA/HSPA/HSPA+ |
| Applications-General Purpose | 89600 VSA Software Analog Demodulation EMI Precompliance Flexible Digital Modulation Analysis MATLAB Noise Figure Phase Noise Pulse Real-Time Spectrum Analysis Remote Language Compatibility SCPI Code Compatibility Stimulus Response |
| Minimum Duration for 100% Probability of Intercept | 3.57 µs |
| General Purpose/Other Applications |
| EMC/EMI, Flexible Digital,Modulation Analysis |
| MATLAB, Noise Figure, Phase Noise, Pulse |
| Cellular Applications and Wireless connectivity with 89601A/B software |
| Code compatible with PSA and other legacy platforms (8566/68, 856x) |
| Expandability |
| Seven expansion slots |
| Removable CPU motherboard |
| Firmware-based measurement applications |
| Windows operating system that lets you run software applications |
| inside the analyzer |
| Mechanical attenuator 2 dB steps, 0 to 70 dB |
| Optional Ele |
| Interfaces |
| RF input connector: 2.4mm(f) 50 Ohm |
| LXI class C compliant, SCPI and IVI-COM |
| USB 2.0, GPIB, and LAN (1000BaseT) |
| Display Resolution: 1024 x 768 XGA |
| Specifications | |
| N9030A PXA Signal Analyzer | |
| Model Overview | |
| Model - Option Number | Description |
| N9030A-503 | Frequency range, 3 Hz to 3.6 GHz |
| N9030A-508 | Frequency range, 3 Hz to 8.4 GHz |
| N9030A-513 | Frequency range, 3 Hz to 13.6 GHz |
| N9030A-526 | Frequency range, 3 Hz to 26.5 GHz |
| N9030A-543 | Frequency range, 3 Hz to 43 GHz |
| N9030A-544 | Frequency range, 3 Hz to 44 GHz |
| N9030A-550 | Frequency range, 3 Hz to 50 GHz |
| Options / Accessories | |
| N9030A-1CM | Rack mount: Adds rack mount flanges to the PXA |
| N9030A-1CN | Front handles: Adds front handles to the PXA |
| N9030A-1CP | Rack mount with handles: Adds rack mount flanges and handles to the PXA |
| N9030A-1CR | Rack slide: Adds a non-tilting rack slide to the PXA |
| N9030A-UK6 | Commercial calibration certificate with test data: Calibration certificate only available at time of instrument purchase; only provides measurement results |
| N9030A-A6J | ANSI Z540-1-1994 Calibration: Provides ANSI Z540 compliant calibration from factory |
| Specifications | |||
| N9030A PXA Signal Analyzer | |||
| Instrument Upgrade Overview | |||
| Upgrade Number | Description | Requirements (PXA must already include the following) | Additional Information |
| N9030AK-F01 | Increase frequency from 3.6 to 8.4 GHz | 503 | -- |
| N9030AK-F02 | Increase frequency from 3.6 to 13.6 GHz | 503 | -- |
| N9030AK-F03 | Increase frequency from 3.6 to 26.5 GHz | 503 | -- |
| N9030AK-F04 | Increase frequency from 3.6 to 44 GHz | 503 | Not compatible with Option BBA |
| N9030AK-F05 | Increase frequency from 3.6 to 50 GHz | 503 | Not compatible with Option BBA |
| N9030AK-F06 | Increase frequency from 8.4 to 13.6 GHz | 508 | -- |
| N9030AK-F07 | Increase frequency from 8.4 to 26.5 GHz | 508 | -- |
| N9030AK-F08 | Increase frequency from 8.4 to 44 GHz | 508 | Not compatible with Option BBA |
| N9030AK-F09 | Increase frequency from 8.4 to 50 GHz | 508 | Not compatible with Option BBA |
| N9030AK-F10 | Increase frequency from 13.6 to 26.5 GHz | 513 | -- |
| N9030AK-F11 | Increase frequency from 13.6 to 44 GHz | 513 | Not compatible with Option BBA |
| N9030AK-F12 | Increase frequency from 13.6 to 50 GHz | 513 | Not compatible with Option BBA |
| N9030AK-F13 | Increase frequency from 26.5 to 44 GHz | 526 | Not compatible with Option BBA |
| N9030AK-F14 | Increase frequency from 26.5 to 50 GHz | 526 | Not compatible with Option BBA |
| N9030AK-F15 | Increase frequency from 43/44 to 50 GHz | 543/544 | Includes 50 GHz preamp |