Configured models contain the following attributes:
Oscilloscopes & Logic AnalyzersSampling Oscilloscopes20GHz <= 50GHzPlease use 'Get Quick Quote' and we’ll contact you and quote for your exact need.
You can also get in touch, if you prefer, and our experts will be able to guide you with the right application and procurement solution for this product.
The Keysight N1092A DCA-M Sampling Oscilloscope (Single Optical Channel) is the fastest throughput with high 250 kHz sample rate with low cost configurations.
High accuracy, low cost solution for optical waveform analysis including solutions for 8.4 through 64 GBaud, very low noise and jitter, fast sampling rates for high throughput, and integrated clock recovery available.
| KEY FEATURES |
| High sensitivity with <5 uW noise |
| Fast throughput with high 250 kHz sample rate |
| Accurate high data-rate analysis with <200 fs jitter |
| Small footprint from compact design |
| Unfiltered bandwidth >40 GHz (option 40A) |
| Integrated clock recovery available (option CDR) |
| SPECIFICATIONS | |
| Model: N1092A | |
| Feature | Parameter |
| Electrical Channels | 0 |
| Optical Channels | 1 |
| Intrinsic Jitter | < 200 fs rms |
| Maximum Electrical Bandwidth | N/A |
| Fiber Mode | Single Mode and Multimode |
| Maximum Optical Bandwidth | 28 GHz |
| SPECIFICATIONS | |
| SX2-Class Sampling Oscilloscope, | |
| Model - Option | Description |
| N1092A | Single Optical Channel Oscilloscope |
| N1092B | Dual Optical Channel Oscilloscope |
| N1092D | Quad Optical Channel Oscilloscope |
| N1092C | Single Optical, Dual Electrical Channel Oscilloscope |
| N1092E | Dual Optical, Dual Electrical Channel Oscilloscope |
| MODEL - OPTION | |
| N1092x-280 | 25.781, 26.563, 27.952, 28.050 Gbaud filters (mandatory) |
| N1092x-30A | 30 GHz amplified SM/MM optical |
| N1092A-N28 | 30 GHz amplified SM/MM optical, 280 kHz high-pass |
| N1092x-40A | 40 GHz amplified SM optical and additional 53.125 GBd hardware filter |
| N1092x-CDR | Add 24-29 and 48-58 GBd Clock Recovery (N1092A/B models only, requires #40A) |
| N1092x-CRX | Extended clock recovery input rates: 125 MBd to 64 GBd (requires #40A and #CDR) |
| N1092x-168 | Add 25.78 Gb/s TDEC filter (only for #30A) |
| N1092x-206 | Add 20.625 Gb/s filter (only for #30A) |
| N1092x-STB | Standard timebase |
| N1092x-LOJ | Low jitter timebase |
| N1092x-PLK | Pattern lock trigger hardware (requires Option LOJ) |
| N1092x-FS1 | Fast sampling rate |
| N1092x-IRC | Impulse response correction (optical channels only) |
| N1092x-C0C | Certificate of calibration |
| N1092x-UK6 | Commercial calibration certificate with test data |
| N1092x-1CM | Single instrument rack mount kit |
| N1092x-1CN | Dual instrument side by side rack mount kit |
| N1010100A | R&D package for FlexDCA (requires options PLK and LOJ) |
| N1010200A | Manufacturing package for FlexDCA requires Options PLK and LOJ) |
| JSA for #CDR | Jitter spectrum analysis will be enabled by N1010100A or N1010300A |
| SPECIFICATIONS | |
| DCA-X Modules Series Overview | |
| Model | Description |
| N1000A | Infiniium DCA-X mainframe |
| 86100D | Infiniium DCA-X Wide-Bandwidth Oscilloscope Mainframe |
| Optical Electrical Modules * | |
| N1030A | Single 65 GHz optical channel, 9/125 μm fiber input |
| N1030B | Two 65 GHz optical channels, 9/125 μm fiber input |
| N1032A | Single 120 GHz optical channel, 9/125 μm fiber input |
| N1032B | Two 120 GHz optical channels, 9/125 μm fiber input |
| Dual/ Quad Electrical Channel Modules * | |
| N1040A | Dual electrical channel module |
| N1045B | 2/4 port 60 GHz electrical remote head |
| N1046A | 100 GHz, 1/2/4 port electrical remote sampling head |
| TDR/TDT Modules * | |
| N1055A ¹ | 35/50 GHz 2/4 Port electrical remote head module with TDR/TDT |
| Precision Waveform Analyzer Module * | |
| N1060A | Precision waveform analyzer ² (6) |
| External Clock Recovery Solutions Module * | |
| N1076B | Electrical clock recovery |
| N1077A | Optical/electrical clock recovery |
| N1077B | Optical/electrical clock recovery |
| N1078A | Optical/electrical clock recovery |
| DCA-M Sampling Oscilloscope Module * | |
| N1090A | Optical sampling oscilloscope |
| Optical DCA-M Sampling Oscilloscope Module * | |
| N1092A | Single optical channel oscilloscope |
| N1092B | Dual optical channel oscilloscope |
| N1092D | Quad optical channel oscilloscope |
| N1092C | Single optical, dual electrical channel oscilloscope |
| N1092E | Dual optical, dual electrical channel oscilloscope |
| Electrical DCA-M Oscilloscope Module * | |
| N1094A | Dual electrical channel oscilloscope |
| N1094B | Quad electrical channel oscilloscope |
Note:
* Please See Data Sheet in Resources for module options
¹ When used in an 86100D, 86100D option ETR is recommended if more than one TDR module is connected to the same DUT
² Module includes a custom System Impulse Response Correction (SIRC) file for each channel .