High Frequency (range) | 100MHz <= 1GHz |
The TPR1000 and TPR4000 probes provide a low-noise measurement solution (oscilloscope and probe), which is critical to not confuse the noise of the oscilloscope and probe with the noise and ripple of the DC supply being measured. The higher input impedance in the probes minimize the oscilloscope loading effect on DC rails (50 kΩ at DC). The probes provide higher bandwidth to see more signal content (harmonics, faster ripples, etc.) on DC rails that could affect data signals, clocks, etc.
The TPR1000 and TPR4000 provide a best-in-class integrity solution for power integrity and validation engineers in the high speed (μP), low power (mobile) and switched-mode power supply markets. The probes are designed to offer the lowest noise with high bandwidth at 60 V offset, flexible connectivity options to cover customers challenges, and software packages to cover the digital power management market.
The added functionality, higher density, and faster switching speeds of modern electronic products drive the need for lower supply voltages. Designers need to zoom-in on power rails to look for high-frequency intruder signals, measure ripple and analyze coupling effects with tighter tolerances. Oscilloscopes often don't have enough offset to shift the noise and ripple on DC rails to the center of the screen to make the needed measurements.
Key Performance Specifications:
1Due to software incompatibilities between the TPR1000 and TPR4000 probes and the MDO3000 and MDO4000C oscilloscopes, the accuracy of probe measurements is reduced when these oscilloscopes are used in vertical scale settings less than 2 mV/division. For all other vertical scale settings, the specified accuracy of the probe is maintained.
2DPO70000 oscilloscopes require the optional TCA-VPI50 adapter.
3Frequency response optimized for <1 Ω source impedance.
4Through SMA-to-SMA cable or Solder Micro-Coax tip.
5Max AC RMS of 1 V.
6Comp box and oscilloscope temperature range limited to 0 to +55 °C.
Applications:
Specifications | |
Bandwidth | TPR1000: 1 GHz |
TPR4000: 4 GHz | |
Offset Voltage Range | ±60 V |
Dynamic Range | ±1 V |
Input Resistance | 50 kΩ DC |
50 Ω AC | |
Input Coupling | DC, LF reject |
Accuracy | 1 mV |
System Noise | <300 μVP-P (with 20 MHz bandwidth limit) ** |
<1.3 mVP-P (at full bandwidth of oscilloscope)** | |
Attenuation | 1.25x * |
Connectivity and Accessories | New browser, solder-in and snap-on |
* Frequency response optimized for <1 Ω source impedance.
** Using 6 Series MSO oscilloscopes. With grounded input and maximum sensitivity set to 1.3 mV/Div.