Geconfigureerde modellen bevatten de volgende opties:
Oscilloscopes & Logic AnalyzersSampling Oscilloscopes20GHz <= 50GHzGebruikt u alstublieft "krijg snel een offerte" , en we zullen u contacteren en een offerte maken voor u.
U kunt ook neem contact op als je dat liever hebt, en onze experts zullen u begeleiden met de juiste applicatie en inkoop oplossing voor dit product.
The Keysight N1055A remote head module is designed to provide fast and accurate impedance and S-parameter measurements on high-speed designs with up to 16 ports.
New digital designs make signal integrity more challenging. That's why the Keysight N1055A remote head module is designed to provide fast and accurate impedance and S-parameter measurements on high-speed designs with up to 16 ports. Configure your DCA-X oscilloscope mainframe with one to four N1055A time-domain reflectometry (TDR) / time-domain transmission (TDT) modules for an economical solution.
| KEY FEATURES |
| Bandwidth options: 35 or 50 GHz (upgradable) |
| Edge speed (10-90%, typical): 18 ps (35 GHz) or 7 ps (50 GHz) |
| Channel options: 2 or 4 per module (upgradable) with independent skew control and up to 16 channels per 86100D mainframe |
| Ultra-thin remote head: 1.6 m phase-stable cable, 2.92 mm (35 GHz) or 1.85 mm (50 GHz) connectors, and integrated 67 GHz diode limiters for ESD/EOS protection |
| TDR fixture de-embedding removes effects of fixtures, cables or probes connected between remote heads and DUT |
| SPECIFICATIONS | |
| Model: N1055A TDR/TDT Remote Sampling Head Module | |
| Feature | Parameter |
| Applications | DCA-X Electrical TDR/TDT Module |
| Operating System | Windows 10 |
| Maximum Memory Depth | N/A |
| Supported Filter Range | N/A |
| Bandwidth Options | Up to 50 GHz |
| Electrical Channels | 4 |
| Optical Channels | 0 |
| Number of Channels | 2 electrical, 4 electrical |
| Module Type | Remote Sampling Head |
| Form Factor | Module |
| Instrument Type | Equivalent-Time |
| Type | Equivalent-Time |
| Maximum Bandwidth | 50 GHz |
| Bandwidth | 50 GHz |
| Wavelength Range | N/A |
| Intrinsic Jitter | 90 fs rms |
| Maximum Sample Rate | 250 kHz |
| Input Type | 1.85 mm, 2.92 mm |
| Maximum Electrical Bandwidth | 50 GHz |
| Maximum Optical Bandwidth | N/A |
| SPECIFICATIONS | |
| Model: N1055A TDR/TDT Remote Sampling Head Module Overview | |
| Model-Option | Description |
| N1055A | 35/50 GHz 2/4 Port electrical remote head module with TDR/TDT |
| N1055A-32F | 35 GHz BW, 2 Channel, 2.92 mm, Female |
| N1055A-32M | 35 GHz BW, 2 Channel, 2.92 mm, Male |
| N1055A-52F | 50 GHz BW, 2 Channel, 1.85 mm, Female |
| N1055A-52M | 50 GHz BW, 2 Channel, 1.85 mm, Male |
| N1055A-34F | 35 GHz BW, 4 Channel, 2.92 mm, Female |
| N1055A-34M | 35 GHz BW, 4 Channel, 2.92 mm, Male |
| N1055A-54F | 50 GHz BW, 4 Channel, 1.85 mm, Female |
| N1055A-54M | 50 GHz BW, 4 Channel, 1.85 mm, Male |
| N1055A-C0C | Certificate of calibration |
| N1055A-UK6 | Commercial calibration certificate with test data |
| N1055A-FS1 | Fast sampling (mandatory on all new shipping units) |
| N1027A-x4y 1 | TDT/TDT accessory kit with DC to 67 GHz ECal module and adapters |
| N4694D-0DC | DC to 67 GHz 2-port 1.85 mm ECal module 2 |
NOTE:
1 x and y of N1027A option must match the N1055A option (e.g., use N1027A-54F for N1055A-52F/54F).
2 Use N469xD with option M0M for N1055A-xxF remote heads, and N469xD-F0F for N1055A-xxM
| SPECIFICATIONS | |
| DCA-X Modules Series Overview | |
| Model | Description |
| N1000A | Infiniium DCA-X mainframe |
| 86100D | Infiniium DCA-X Wide-Bandwidth Oscilloscope Mainframe |
| Optical Electrical Modules * | |
| N1030A | Single 65 GHz optical channel, 9/125 μm fiber input |
| N1030B | Two 65 GHz optical channels, 9/125 μm fiber input |
| N1032A | Single 120 GHz optical channel, 9/125 μm fiber input |
| N1032B | Two 120 GHz optical channels, 9/125 μm fiber input |
| Dual/ Quad Electrical Channel Modules * | |
| N1040A | Dual electrical channel module |
| N1045B | 2/4 port 60 GHz electrical remote head |
| N1046A | 100 GHz, 1/2/4 port electrical remote sampling head |
| TDR/TDT Modules * | |
| N1055A ¹ | 35/50 GHz 2/4 Port electrical remote head module with TDR/TDT |
| Precision Waveform Analyzer Module * | |
| N1060A | Precision waveform analyzer ² (6) |
| External Clock Recovery Solutions Module * | |
| N1076B | Electrical clock recovery |
| N1077A | Optical/electrical clock recovery |
| N1077B | Optical/electrical clock recovery |
| N1078A | Optical/electrical clock recovery |
| DCA-M Sampling Oscilloscope Module * | |
| N1090A | Optical sampling oscilloscope |
| Optical DCA-M Sampling Oscilloscope Module * | |
| N1092A/B/D | Single optical channel oscilloscope |
| N1092B | Dual optical channel oscilloscope |
| N1092D | Quad optical channel oscilloscope |
| N1092C | Single optical, dual electrical channel oscilloscope |
| N1092E | Dual optical, dual electrical channel oscilloscope |
| Electrical DCA-M Oscilloscope Module * | |
| N1094A | Dual electrical channel oscilloscope |
| N1094B | Quad electrical channel oscilloscope |
Note:
* Please See Data Sheet in Resources for module options
¹ When used in an 86100D, 86100D option ETR is recommended if more than one TDR module is connected to the same DUT
² Module includes a custom System Impulse Response Correction (SIRC) file for each channel .